MD61-SC2
已停產
Intel® C621 Chipset
- 2nd Gen. Intel® Xeon® Scalable and Intel® Xeon® Scalable Processors
- 6-Channel RDIMM/LRDIMM DDR4 per processor, 16 x DIMMs
- Supports Intel® Optane™ DC Persistent Memory
- 2 x 10Gb/s SFP+ and 2 x 1Gb/s LAN ports
- 1 x Dedicated management port
- 3 x SlimSAS (for 12 x SATA 6Gb/s) ports
- 2 x SATA DOM supported
- 2 x U.2 with PCIe Gen3 x4 interface
- Up to 4 PCIe Gen3 expansion slots
- 1 x mezzanine type slot with PCIe Gen3 x16 interface
- Aspeed® AST2500 remote management controller
* 以上產品之規格、圖片及其他資訊僅供參考,如與實際產品有任何不相符之處,應以實際產品為準。技嘉科技保留在任何時間做出修改之權利。對任何因使用上述資料而引致之損失,技嘉科技概不承擔任何責任。
* 本產品所標示之各項效能表現為各晶片廠商或各制定介面官方組織所提出的最大理論值,實際效能可能因規格及設備而有所不同。
* 本文中所使用之各項商標及企業識別圖示,均為其合法所有人之財產。
* 基於PC基本架構,有部分記憶體空間須留作系統用途,故所偵測到之記憶體大小會比實際上較少。
* 本產品所標示之各項效能表現為各晶片廠商或各制定介面官方組織所提出的最大理論值,實際效能可能因規格及設備而有所不同。
* 本文中所使用之各項商標及企業識別圖示,均為其合法所有人之財產。
* 基於PC基本架構,有部分記憶體空間須留作系統用途,故所偵測到之記憶體大小會比實際上較少。
SPECIFICATIONS
Board Size
E-ATX
305W x 330D (mm)
305W x 330D (mm)
Processor Supported
2nd Generation Intel® Xeon® Scalable and Intel® Xeon® Scalable Processors
Intel® Xeon® Platinum Processor, Intel® Xeon® Gold Processor, Intel® Xeon® Silver Processor and Intel® Xeon® Bronze Processor
NOTE: If only 1 CPU is installed, some PCIe or memory functions might be unavailable
Intel® Xeon® Platinum Processor, Intel® Xeon® Gold Processor, Intel® Xeon® Silver Processor and Intel® Xeon® Bronze Processor
NOTE: If only 1 CPU is installed, some PCIe or memory functions might be unavailable
Socket
Chipset Description
Intel® C621 Chipset
Memory Type
16 x DIMM slots
DDR4 memory supported only
6-channel memory per processor architecture
RDIMM modules up to 128GB supported
LRDIMM modules up to 128GB supported
Supports Intel® Optane™ DC Persistent Memory (DCPMM)
1.2V modules: 2933/2666/2400/2133 MHz
Maximum verified DCPMM configuration:
* Ambient temperature 35°C
* 2nd Generation Intel® Xeon® Scalable processor 205W (Max.)
* DCPMM 256GB x4 pcs
DCPMM installation locations:
DIMM_P0_(A1, D1)
DIMM_P1_(G1, J1)
NOTE:
1. 2933MHz for 2nd Generation Intel® Xeon® Scalable Processors only
2. Intel® Optane™ DC Persistent Memory for 2nd Generation Intel® Xeon® Scalable Processors only
3. The maximum number of DCPMM that can be installed is based on a maximum operating (ambient) temperature of 35°C
4. To enquire about installing a greater number of DCPMM, please consult with your GIGABYTE technical or sales representative
DDR4 memory supported only
6-channel memory per processor architecture
RDIMM modules up to 128GB supported
LRDIMM modules up to 128GB supported
Supports Intel® Optane™ DC Persistent Memory (DCPMM)
1.2V modules: 2933/2666/2400/2133 MHz
Maximum verified DCPMM configuration:
* Ambient temperature 35°C
* 2nd Generation Intel® Xeon® Scalable processor 205W (Max.)
* DCPMM 256GB x4 pcs
DCPMM installation locations:
DIMM_P0_(A1, D1)
DIMM_P1_(G1, J1)
NOTE:
1. 2933MHz for 2nd Generation Intel® Xeon® Scalable Processors only
2. Intel® Optane™ DC Persistent Memory for 2nd Generation Intel® Xeon® Scalable Processors only
3. The maximum number of DCPMM that can be installed is based on a maximum operating (ambient) temperature of 35°C
4. To enquire about installing a greater number of DCPMM, please consult with your GIGABYTE technical or sales representative
Integrated Network
2 x 10Gb/s SFP+ LAN ports (QLogic® QL41102)
2 x 1Gb/s LAN ports
1 x 10/100/1000 management LAN
2 x 1Gb/s LAN ports
1 x 10/100/1000 management LAN
Integrated Video Controller
Integrated in Aspeed® AST2500
2D Video Graphic Adapter with PCIe bus interface
1920x1200@60Hz 32bpp, DDR4 SDRAM
2D Video Graphic Adapter with PCIe bus interface
1920x1200@60Hz 32bpp, DDR4 SDRAM
Integrated Audio Controller
N/A
Integrated SAS Controller
N/A
Integrated SATA Controller
3 x SlimSAS for 12 x SATA III 6Gb/s ports
2 x 7-pin SATA III 6Gb/s with SATA DOM supported
2 x 7-pin SATA III 6Gb/s with SATA DOM supported
Support RAID Function
Intel® SATA RAID 0/1/10/5
Expansion Slot
Slot_7 (PCIe_4): 1 x PCIe x16 (Gen3 x16 bus) slot from CPU_1
Slot_6 (PCIe_3): 1 x PCIe x16 (Gen3 x16 bus) slot from CPU_1
Slot_5 (PCIe_2): 1 x PCIe x16 (Gen3 x16 bus) slot from CPU_1
Slot_4 (PCIe_1): 1 x PCIe x16 (Gen3 x16 bus) slot from CPU_0
1 x Mezzanine card slot:
- PCIe Gen3 x16 (x8+x8)
- From CPU_0
- Optional for OCP mezzanine card with low profile type
2 x U.2 ports:
- SlimSAS type
- PCIe Gen3 x4 per port
- From CPU_0
- Shared with Mezzanine card x8 signal
- For GIGABYTE server system backplane board use only
Slot_6 (PCIe_3): 1 x PCIe x16 (Gen3 x16 bus) slot from CPU_1
Slot_5 (PCIe_2): 1 x PCIe x16 (Gen3 x16 bus) slot from CPU_1
Slot_4 (PCIe_1): 1 x PCIe x16 (Gen3 x16 bus) slot from CPU_0
1 x Mezzanine card slot:
- PCIe Gen3 x16 (x8+x8)
- From CPU_0
- Optional for OCP mezzanine card with low profile type
2 x U.2 ports:
- SlimSAS type
- PCIe Gen3 x4 per port
- From CPU_0
- Shared with Mezzanine card x8 signal
- For GIGABYTE server system backplane board use only
On-Board Connector
1 x 24-pin ATX main power connector
2 x 8-pin ATX 12V power connectors
2 x SATA DOM power pin headers
5 x SlimSAS connectors
2 x 7-pin SATA connectors
2 x CPU fan headers
5 x System fan headers
1 x USB 3.0 header
1 x COM_1 header
1 x TPM header
1 x VROC connector
1 x Front panel header
1 x HDD back plane board header
1 x PMBus connector
1 x IPMB connector
1 x Clear CMOS jumper
1 x BIOS recovery jumper
1 x Case open header
1 x Buzzer
2 x 8-pin ATX 12V power connectors
2 x SATA DOM power pin headers
5 x SlimSAS connectors
2 x 7-pin SATA connectors
2 x CPU fan headers
5 x System fan headers
1 x USB 3.0 header
1 x COM_1 header
1 x TPM header
1 x VROC connector
1 x Front panel header
1 x HDD back plane board header
1 x PMBus connector
1 x IPMB connector
1 x Clear CMOS jumper
1 x BIOS recovery jumper
1 x Case open header
1 x Buzzer
Rear I/O Connectors
2 x USB 3.0
1 x VGA
2 x SFP+
2 x RJ45
1 x MLAN
1 x ID button with LED
2 x LAN activity LEDs
1 x VGA
2 x SFP+
2 x RJ45
1 x MLAN
1 x ID button with LED
2 x LAN activity LEDs
TPM
1 x TPM header with SPI interface
Optional TPM2.0 kit: CTM010
Optional TPM2.0 kit: CTM010
OS Driver Supported
For Skylake processors:
Windows Server 2012 R2 with Update
Windows Server 2016
Windows Server 2019
Red Hat Enterprise Linux 6.9 (x64) or later
Red Hat Enterprise Linux 7.3 (x64) or later
Red Hat Enterprise Linux 8.0 (x64) or later
Red Hat Enterprise Linux 9.0 (x64) or later
SUSE Linux Enterprise Server 11 SP4 (x64) or later
SUSE Linux Enterprise Server 12 SP2 (x64) or later
SUSE Linux Enterprise Server 15 (x64) or later
Ubuntu 16.04.1 LTS (x64) or later
Ubuntu 18.04 LTS (x64) or later
Ubuntu 20.04 LTS (x64) or later
VMware ESXi 6.0 Update3 or later
VMware ESXi 6.5 or later
VMware ESXi 6.7 or later
VMware ESXi 7.0 or later
VMware ESXi 8.0 or later
Citrix Xenserver 7.1.0 CU2 or later
Citrix Xenserver 7.4.0 or later
Citrix Hypervisor 8.0.0 or later
For Cascade Lake processors:
Windows Server 2012 R2 with Update
Windows Server 2016
Windows Server 2019
Red Hat Enterprise Linux 7.6 (x64) or later
Red Hat Enterprise Linux 8.0 (x64) or later
Red Hat Enterprise Linux 9.0 (x64) or later
SUSE Linux Enterprise Server 12 SP3 (x64) or later
SUSE Linux Enterprise Server 15 (x64) or later
Ubuntu 18.04 LTS (x64) or later
Ubuntu 20.04 LTS (x64) or later
Ubuntu 22.04 LTS (x64) or later
VMware ESXi 6.0 Update3 or later
VMware ESXi 6.5 Update2 or later
VMware ESXi 6.7 Update1 or later
VMware ESXi 7.0 or later
VMware ESXi 8.0 or later
Citrix Xenserver 7.1.0 CU2 or later
Citrix Xenserver 7.5.0 or later
Citrix Hypervisor 8.0.0 or later
Windows Server 2012 R2 with Update
Windows Server 2016
Windows Server 2019
Red Hat Enterprise Linux 6.9 (x64) or later
Red Hat Enterprise Linux 7.3 (x64) or later
Red Hat Enterprise Linux 8.0 (x64) or later
Red Hat Enterprise Linux 9.0 (x64) or later
SUSE Linux Enterprise Server 11 SP4 (x64) or later
SUSE Linux Enterprise Server 12 SP2 (x64) or later
SUSE Linux Enterprise Server 15 (x64) or later
Ubuntu 16.04.1 LTS (x64) or later
Ubuntu 18.04 LTS (x64) or later
Ubuntu 20.04 LTS (x64) or later
VMware ESXi 6.0 Update3 or later
VMware ESXi 6.5 or later
VMware ESXi 6.7 or later
VMware ESXi 7.0 or later
VMware ESXi 8.0 or later
Citrix Xenserver 7.1.0 CU2 or later
Citrix Xenserver 7.4.0 or later
Citrix Hypervisor 8.0.0 or later
For Cascade Lake processors:
Windows Server 2012 R2 with Update
Windows Server 2016
Windows Server 2019
Red Hat Enterprise Linux 7.6 (x64) or later
Red Hat Enterprise Linux 8.0 (x64) or later
Red Hat Enterprise Linux 9.0 (x64) or later
SUSE Linux Enterprise Server 12 SP3 (x64) or later
SUSE Linux Enterprise Server 15 (x64) or later
Ubuntu 18.04 LTS (x64) or later
Ubuntu 20.04 LTS (x64) or later
Ubuntu 22.04 LTS (x64) or later
VMware ESXi 6.0 Update3 or later
VMware ESXi 6.5 Update2 or later
VMware ESXi 6.7 Update1 or later
VMware ESXi 7.0 or later
VMware ESXi 8.0 or later
Citrix Xenserver 7.1.0 CU2 or later
Citrix Xenserver 7.5.0 or later
Citrix Hypervisor 8.0.0 or later
Server Management
Aspeed® AST2500 management controller
GIGABYTE Management Console (AMI MegaRAC SP-X) web interface
GIGABYTE Management Console (AMI MegaRAC SP-X) web interface
- Dashboard
- JAVA Based Serial Over LAN
- HTML5 KVM
- Sensor Monitor (Voltage, RPM, Temperature, CPU Status …etc.)
- Sensor Reading History Data
- FRU Information
- SEL Log in Linear Storage / Circular Storage Policy
- Hardware Inventory
- Fan Profile
- System Firewall
- Power Consumption
- Power Control
- LDAP / AD / RADIUS Support
- Backup & Restore Configuration
- Remote BIOS/BMC/CPLD Update
- Event Log Filter
- User Management
- Media Redirection Settings
- PAM Order Settings
- SSL Settings
- SMTP Settings
PSU Connector
1 x 24-pin ATX main power connector
2 x 8-pin ATX 12V power connectors
2 x 8-pin ATX 12V power connectors
Operating Properties
Operating temperature: 10°C to 40°C
Operating humidity: 8-80% (non-condensing)
Non-operating temperature: -40°C to 60°C
Non-operating humidity: 20%-95% (non-condensing)
Operating humidity: 8-80% (non-condensing)
Non-operating temperature: -40°C to 60°C
Non-operating humidity: 20%-95% (non-condensing)
Packaging Bundle
1 x MD61-SC2
1 x I/O shield
1 x Quick start guide
2 x SlimSAS for 8 x SATAIII 6Gb/s 600mm cables
2 x Non-Fabric CPU carrier
Single Box dimensions: 409 x 355 x 78 mm
Carton dimension: 729 x 415 x 432 mm
Quantity: 10 x single box with one carton
1 x I/O shield
1 x Quick start guide
2 x SlimSAS for 8 x SATAIII 6Gb/s 600mm cables
2 x Non-Fabric CPU carrier
Single Box dimensions: 409 x 355 x 78 mm
Carton dimension: 729 x 415 x 432 mm
Quantity: 10 x single box with one carton
Bulk Packaging Content
10 x MD61-SC2
10 x I/O shields
20 x Non-Fabric CPU carrier
Carton dimensions: 473 x 600 x 495 mm
10 x I/O shields
20 x Non-Fabric CPU carrier
Carton dimensions: 473 x 600 x 495 mm
Ordering Information
Retail: 9MD61SC2MR-00
Bulk: 9MD61SC2NR-00
Bulk: 9MD61SC2NR-00
* 產品規格會依各國家地區出貨而有所變動,應以各地實際出貨狀況為準。誠摯建議與當地經銷商或零售商確認最新產品販售規格。
* 以上產品之規格、圖片及其他資訊僅供參考,如與實際產品有任何不相符之處,應以實際產品為準。技嘉科技保留在任何時間做出修改之權利。對任何因使用上述資料而引致之損失,技嘉科技概不承擔任何責任。
* 本產品所標示之各項效能表現為各晶片廠商或各制定介面官方組織所提出的最大理論值,實際效能可能因規格及設備而有所不同。
* 本文中所使用之各項商標及企業識別圖示,均為其合法所有人之財產。
* 基於PC基本架構,有部分記憶體空間須留作系統用途,故所偵測到之記憶體大小會比實際上較少。
* 以上產品之規格、圖片及其他資訊僅供參考,如與實際產品有任何不相符之處,應以實際產品為準。技嘉科技保留在任何時間做出修改之權利。對任何因使用上述資料而引致之損失,技嘉科技概不承擔任何責任。
* 本產品所標示之各項效能表現為各晶片廠商或各制定介面官方組織所提出的最大理論值,實際效能可能因規格及設備而有所不同。
* 本文中所使用之各項商標及企業識別圖示,均為其合法所有人之財產。
* 基於PC基本架構,有部分記憶體空間須留作系統用途,故所偵測到之記憶體大小會比實際上較少。
SUPPORT
驅動程式
BIOS
工具程式
Firmware
QVL
- All
- All
- Windows Server 2019
- Windows Server 2016 64bit
- Windows Server 2012 R2 64bit
- Ubuntu 16.04.2 LTS x64
- Ubuntu 14.04.5 LTS x64
- SLES 12.2 x64
- SLES 11.4 x64
- RHEL 7.3 x64
- RHEL 6.9 x64
- Linux
晶片組
晶片組
版本
檔案大小
日期
Intel® Chipset Driver
Version : 10.1.17861.8101
3.34 MB
Apr 18, 2019
作業系統: Windows Server 2012 R2 64bit,Windows Server 2016 64bit,Windows Server 2019
Intel® Chipset Driver
Version : 10.1.18228.8176
3.12 MB
Dec 29, 2019
作業系統: Windows Server 2012 R2 64bit,Windows Server 2016 64bit,Windows Server 2019
網路介面
網路介面
版本
檔案大小
日期
QLogic LAN Driver
Version : 18.80.1.2
8.43 MB
Aug 21, 2017
作業系統: Windows Server 2012 R2 64bit,Windows Server 2016 64bit
QLogic LAN Driver
Version : 8.18.16.0
12.27 MB
Aug 21, 2017
作業系統: SLES 11.4 x64,RHEL 7.3 x64,SLES 12.2 x64,Ubuntu 16.04.2 LTS x64,Ubuntu 14.04.5 LTS x64,RHEL 6.9 x64
SATA RAID/AHCI
SATA RAID/AHCI
版本
檔案大小
日期
Intel® SATA Preinstall driver
(For AHCI / RAID Mode)
Note: Windows setup to read from USB devices
(For AHCI / RAID Mode)
Note: Windows setup to read from USB devices
Version : 6.0.0.1357
6.54 MB
Apr 19, 2019
作業系統: Windows Server 2012 R2 64bit,Windows Server 2016 64bit,Windows Server 2019
Intel® Rapid Storage Technology enterprise (Intel® RSTe)
Version : 6.0.0.1357
265.09 MB
Apr 21, 2019
作業系統: Windows Server 2012 R2 64bit,Windows Server 2016 64bit,Windows Server 2019
公用程式
BIOS
說明
版本
檔案大小
日期
Update for security: Vulnerabilities in EDK2 NetworkPkg include CVE-2023-45236, CVE-
2023-45237.
Version : R22
20.27 MB
May 27, 2024
Windows and UEFI mode flash BIOS SOP
Please download BIOS update tool from AMI Website
Please download BIOS update tool from AMI Website
-
0.31 MB
Jan 29, 2021
Warning:
更新BIOS有其潛在的風險,如果您使用目前版本的BIOS沒有問題,我們建議您不要任意更新BIOS。如需更新BIOS,請小心的執行,以避免不當的操作而造成系統毀損.
什麼是 BETA 版?
BETA版是正式推出前的試用版本。雖然該版本已經過測試,但可能還存在部份尚未發現、可能影響執行效能和功能的小問題。 請注意BETA版非正式的版本,並請密切注意正式版本的推出。
更新BIOS有其潛在的風險,如果您使用目前版本的BIOS沒有問題,我們建議您不要任意更新BIOS。如需更新BIOS,請小心的執行,以避免不當的操作而造成系統毀損.
什麼是 BETA 版?
BETA版是正式推出前的試用版本。雖然該版本已經過測試,但可能還存在部份尚未發現、可能影響執行效能和功能的小問題。 請注意BETA版非正式的版本,並請密切注意正式版本的推出。
- All
- All
- Windows Server 2022
- Windows Server 2019
- Windows Server 2016 R2 64bit
- Windows Server 2016 64bit
- Windows Server 2012 R2 64bit
- Windows Server 2012 64bit
- Windows 10 64bit
- VMware
- Ubuntu
- Linux CentOS
- Linux
工具程式
說明
版本
檔案大小
日期
GSM CLI
Version : 2.1.77
147.89 MB
Sep 27, 2024
作業系統: Windows Server 2012 64bit,Windows Server 2012 R2 64bit,Linux CentOS,Windows 10 64bit,Ubuntu,Windows Server 2016 R2 64bit,Windows Server 2019,Windows Server 2022
GSM Server
Version : 2.12
926.33 MB
Jan 18, 2023
作業系統: Linux,Windows Server 2016 64bit,Windows Server 2019
GSM Agent
Version : 2.5
720.29 MB
Dec 27, 2021
作業系統: Linux,Windows Server 2016 64bit,Windows Server 2019
使用手冊
說明
版本
檔案大小
日期
User Guide - BIOS setup manual (Intel Purley platform)
Version : 1.0
19.52 MB
Aug 17, 2017
英語
說明
版本
檔案大小
日期
RESOURCES
Success Case
Video
News
Security & Technical Advisory
Others
Back to MD61-SC2