S252-ZC0
Storage Server - AMD EPYC™ 7003/7002 - 2U DP 24+2-Bay Gen4 NVMe/SATA/SAS
- Hardware-level root of trust support
- Dual AMD EPYC™ 7003/7002 Series Processors
- 8-Channel DDR4 RDIMM/LRDIMM, 16 x DIMMs
- 24 x 3.5"/2.5" SATA/SAS hot-swappable bays
- 2 x 2.5" Gen4 NVMe/SATA/SAS hot-swappable bays on the rear side
- Onboard 12Gb/s SAS expander
- 2 x SATA DOM supported
- 6 x LP PCIe Gen4 x16 slots
- 1+1 1300W 80 PLUS Platinum redundant power supplies (-A00)
- 1+1 1300W 80 PLUS Titanium redundant power supplies (-AT0)
* 以上產品之規格、圖片及其他資訊僅供參考,如與實際產品有任何不相符之處,應以實際產品為準。技嘉科技保留在任何時間做出修改之權利。對任何因使用上述資料而引致之損失,技嘉科技概不承擔任何責任。
* 本產品所標示之各項效能表現為各晶片廠商或各制定介面官方組織所提出的最大理論值,實際效能可能因規格及設備而有所不同。
* 本文中所使用之各項商標及企業識別圖示,均為其合法所有人之財產。
* 基於PC基本架構,有部分記憶體空間須留作系統用途,故所偵測到之記憶體大小會比實際上較少。
* 本產品所標示之各項效能表現為各晶片廠商或各制定介面官方組織所提出的最大理論值,實際效能可能因規格及設備而有所不同。
* 本文中所使用之各項商標及企業識別圖示,均為其合法所有人之財產。
* 基於PC基本架構,有部分記憶體空間須留作系統用途,故所偵測到之記憶體大小會比實際上較少。
SPECIFICATIONS
Dimensions (WxHxD, mm)
2U
438 x 87 x 880
438 x 87 x 880
Motherboard
MZC2-CE0
CPU
AMD EPYC™ 7003 Series Processors
AMD EPYC™ 7002 Series Processors
Dual processor, 7nm technology
Up to 64 cores, 128 threads per processor
cTDP up to 200W
Note: If only 1 CPU is installed, some PCIe or memory functions might be unavailable
AMD EPYC™ 7002 Series Processors
Dual processor, 7nm technology
Up to 64 cores, 128 threads per processor
cTDP up to 200W
Note: If only 1 CPU is installed, some PCIe or memory functions might be unavailable
Socket
2 x LGA 4094
Socket SP3
Socket SP3
Chipset
System on Chip
Memory
16 x DIMM slots
DDR4 memory supported only
8-Channel memory architecture
RDIMM up to 128GB supported
LRDIMM up to 128GB supported
3DS RDIMM/LRDIMM up to 256GB supported
Memory speed: Up to 3200 MT/s
DDR4 memory supported only
8-Channel memory architecture
RDIMM up to 128GB supported
LRDIMM up to 128GB supported
3DS RDIMM/LRDIMM up to 256GB supported
Memory speed: Up to 3200 MT/s
LAN
Rear side:
1 x 10/100/1000 Mbps Management LAN
1 x 10/100/1000 Mbps Management LAN
Video
Integrated in Aspeed® AST2500
2D Video Graphic Adapter with PCIe bus interface
1920x1200@60Hz 32bpp
2D Video Graphic Adapter with PCIe bus interface
1920x1200@60Hz 32bpp
Storage
Side-accessed:
24 x 3.5"/2.5" SATA/SAS hot-swappable bays
LSI SAS35x36R expander
SAS card is required to enable the 24 drive bays
Rear side:
2 x 2.5" Gen4 NVMe/SATA/SAS hot-swappable bays
Default configuration supports:
2 x 2.5" Gen4 NVMe/SATA/SAS drives on the rear side
Recommend optional 12Gb/s SAS cards:
Broadcom MegaRAID 9560-8i Storage Adapter
Broadcom HBA 9500-8i Storage Adapter
CRA4448 (Hardware RAID Card)
CSA4648 (Software HBA Card)
24 x 3.5"/2.5" SATA/SAS hot-swappable bays
LSI SAS35x36R expander
SAS card is required to enable the 24 drive bays
Rear side:
2 x 2.5" Gen4 NVMe/SATA/SAS hot-swappable bays
Default configuration supports:
2 x 2.5" Gen4 NVMe/SATA/SAS drives on the rear side
Recommend optional 12Gb/s SAS cards:
Broadcom MegaRAID 9560-8i Storage Adapter
Broadcom HBA 9500-8i Storage Adapter
CRA4448 (Hardware RAID Card)
CSA4648 (Software HBA Card)
SAS
Supported via SAS add-in cards
RAID
Depends on SAS add-in cards
Expansion Slots
3 x PCIe x16 (Gen4 x16) low-profile slots, from CPU_0
3 x PCIe x16 (Gen4 x16) low-profile slots, from CPU_1
3 x PCIe x16 (Gen4 x16) low-profile slots, from CPU_1
Internal I/O
1 x TPM header
Front I/O
2 x USB 3.0
1 x Power button with LED
1 x ID button with LED
1 x Reset button
1 x Storage activity LED
1 x System status LED
1 x Power button with LED
1 x ID button with LED
1 x Reset button
1 x Storage activity LED
1 x System status LED
Rear I/O
2 x USB 3.0
1 x VGA
1 x MLAN
1 x Power button with LED
1 x ID button with LED
1 x System status LED
1 x VGA
1 x MLAN
1 x Power button with LED
1 x ID button with LED
1 x System status LED
Backplane Board
Left side - CBPD2C0: 12 x 3.5"/2.5" SATA/SAS ports with expander
Right side - CBPD2C1: 12 x 3.5"/2.5" SATA/SAS ports
Rear side - CBPD020: 2 x 2.5" Gen4 NVMe/SATA/SAS ports
Right side - CBPD2C1: 12 x 3.5"/2.5" SATA/SAS ports
Rear side - CBPD020: 2 x 2.5" Gen4 NVMe/SATA/SAS ports
TPM
1 x TPM header with SPI interface
- Optional TPM2.0 kit: CTM010
- Optional TPM2.0 kit: CTM010
Power Supply
1+1 1300W 80 PLUS Platinum redundant power supplies (-A00)
AC Input:
- 100-240V~/ 12-7A, 50-60Hz
- 200-240V~/ 8A, 50-60Hz
DC Input: (Only for China)
- 240Vdc/ 6.5A
DC Output:
- Max 1000W/ 100-240V~
+12V/ 80.5A
+12Vsb/ 3A
- Max 1300W/ 200-240V~ or 240Vdc Input
+12V/ 105.4A
+12Vsb/ 3A
1+1 1300W 80 PLUS Titanium redundant power supplies (-AT0)
AC Input:
- 100-127V~/ 12A, 50-60Hz
- 200-240V~/ 8A, 50-60Hz
DC Input: (Only for China)
- 240Vdc/ 7A
DC Output:
- Max 1000W/ 100-127V~
+12.2V/ 82A
+12.2Vsb/ 3A
- Max 1300W/ 200-240V~ or 240Vdc Input
+12.2V/ 106A
+12.2Vsb/ 3A
AC Input:
- 100-240V~/ 12-7A, 50-60Hz
- 200-240V~/ 8A, 50-60Hz
DC Input: (Only for China)
- 240Vdc/ 6.5A
DC Output:
- Max 1000W/ 100-240V~
+12V/ 80.5A
+12Vsb/ 3A
- Max 1300W/ 200-240V~ or 240Vdc Input
+12V/ 105.4A
+12Vsb/ 3A
1+1 1300W 80 PLUS Titanium redundant power supplies (-AT0)
AC Input:
- 100-127V~/ 12A, 50-60Hz
- 200-240V~/ 8A, 50-60Hz
DC Input: (Only for China)
- 240Vdc/ 7A
DC Output:
- Max 1000W/ 100-127V~
+12.2V/ 82A
+12.2Vsb/ 3A
- Max 1300W/ 200-240V~ or 240Vdc Input
+12.2V/ 106A
+12.2Vsb/ 3A
System Management
Aspeed® AST2500 management controller
GIGABYTE Management Console (AMI MegaRAC SP-X) web interface
GIGABYTE Management Console (AMI MegaRAC SP-X) web interface
- Dashboard
- HTML5 KVM
- Sensor Monitor (Voltage, RPM, Temperature, CPU Status …etc.)
- Sensor Reading History Data
- FRU Information
- SEL Log in Linear Storage/Circular Storage Policy
- Hardware Inventory
- Fan Profile
- System Firewall
- Power Consumption
- Power Control
- LDAP / AD / RADIUS Support
- Backup & Restore Configuration
- Remote BIOS/BMC/CPLD Update
- Event Log Filter
- User Management
- Media Redirection Settings
- PAM Order Settings
- SSL Settings
- SMTP Settings
OS Compatibility
Citrix Hypervisor 8.2.1 or later
Red Hat Enterprise Linux 8.3 (x64) or later
Red Hat Enterprise Linux 9.0 (x64) or later
SUSE Linux Enterprise Server 12 SP5 (x64) or later
SUSE Linux Enterprise Server 15 SP2 (x64) or later
Ubuntu 18.04.5 LTS (x64) or later
Ubuntu 20.04 LTS (x64) or later
Ubuntu 22.04 LTS (x64) or later
VMware ESXi 6.7 Update3 P03 or later
VMware ESXi 7.0 Update1 or later
VMware ESXi 8.0 or later
Windows Server 2016 (X2APIC/256T not supported)
Windows Server 2019
Windows Server 2022
Red Hat Enterprise Linux 8.3 (x64) or later
Red Hat Enterprise Linux 9.0 (x64) or later
SUSE Linux Enterprise Server 12 SP5 (x64) or later
SUSE Linux Enterprise Server 15 SP2 (x64) or later
Ubuntu 18.04.5 LTS (x64) or later
Ubuntu 20.04 LTS (x64) or later
Ubuntu 22.04 LTS (x64) or later
VMware ESXi 6.7 Update3 P03 or later
VMware ESXi 7.0 Update1 or later
VMware ESXi 8.0 or later
Windows Server 2016 (X2APIC/256T not supported)
Windows Server 2019
Windows Server 2022
System Fans
6 x 60x60x38mm hot-swappable fan modules
Operating Properties
Operating temperature: 10°C to 35°C
Operating humidity: 8-80% (non-condensing)
Non-operating temperature: -40°C to 60°C
Non-operating humidity: 20%-95% (non-condensing)
Operating humidity: 8-80% (non-condensing)
Non-operating temperature: -40°C to 60°C
Non-operating humidity: 20%-95% (non-condensing)
Packaging Dimensions
1168 x 697 x 341 mm
Packaging Content
1 x S252-ZC0
2 x CPU heatsinks
1 x 2-Section Rail kit
1 x Cable Management Arm
2 x CPU heatsinks
1 x 2-Section Rail kit
1 x Cable Management Arm
Part Numbers
- Barebone package: 6NS252ZC0MR-00-A*
- Motherboard: 9MZC2CE0NR-00
- 2-Section Rail kit: 25HB2-A66124-C0R
- Cable Management Arm: 25HBZ-R18100-K0R
- CPU heatsink: 25ST1-453211-A3R
- Backplane board - CBPD020: 9CBPD020NR-00
- Backplane board - CBPD2C0: 9CBPD2C0NR-00
- Backplane board - CBPD2C1: 9CBPD2C1NR-00
- Power supply (-A00): 25EP0-213001-F3S
- Power supply (-AT0): 25EP0-21300C-G1S
Optional parts:
- 12Gb/s SAS H/W RAID card : 9CRA4448NR-00
- 12Gb/s SAS S/W RAID card : 9CSA4648NR-00
- RMA packaging: 6NS252ZC0SR-RMA-A100
- Motherboard: 9MZC2CE0NR-00
- 2-Section Rail kit: 25HB2-A66124-C0R
- Cable Management Arm: 25HBZ-R18100-K0R
- CPU heatsink: 25ST1-453211-A3R
- Backplane board - CBPD020: 9CBPD020NR-00
- Backplane board - CBPD2C0: 9CBPD2C0NR-00
- Backplane board - CBPD2C1: 9CBPD2C1NR-00
- Power supply (-A00): 25EP0-213001-F3S
- Power supply (-AT0): 25EP0-21300C-G1S
Optional parts:
- 12Gb/s SAS H/W RAID card : 9CRA4448NR-00
- 12Gb/s SAS S/W RAID card : 9CSA4648NR-00
- RMA packaging: 6NS252ZC0SR-RMA-A100
* 產品規格會依各國家地區出貨而有所變動,應以各地實際出貨狀況為準。誠摯建議與當地經銷商或零售商確認最新產品販售規格。
* 以上產品之規格、圖片及其他資訊僅供參考,如與實際產品有任何不相符之處,應以實際產品為準。技嘉科技保留在任何時間做出修改之權利。對任何因使用上述資料而引致之損失,技嘉科技概不承擔任何責任。
* 本產品所標示之各項效能表現為各晶片廠商或各制定介面官方組織所提出的最大理論值,實際效能可能因規格及設備而有所不同。
* 本文中所使用之各項商標及企業識別圖示,均為其合法所有人之財產。
* 基於PC基本架構,有部分記憶體空間須留作系統用途,故所偵測到之記憶體大小會比實際上較少。
* 以上產品之規格、圖片及其他資訊僅供參考,如與實際產品有任何不相符之處,應以實際產品為準。技嘉科技保留在任何時間做出修改之權利。對任何因使用上述資料而引致之損失,技嘉科技概不承擔任何責任。
* 本產品所標示之各項效能表現為各晶片廠商或各制定介面官方組織所提出的最大理論值,實際效能可能因規格及設備而有所不同。
* 本文中所使用之各項商標及企業識別圖示,均為其合法所有人之財產。
* 基於PC基本架構,有部分記憶體空間須留作系統用途,故所偵測到之記憶體大小會比實際上較少。
SUPPORT
驅動程式
BIOS
工具程式
Firmware
QVL
- All
- All
- Windows Server 2022
- Windows Server 2019
- Windows Server 2016 64bit
晶片組
BIOS
說明
版本
檔案大小
日期
1) Updated to AGESA RomePI 1.0.0.J.
2) Updated to AGESA MilanPI 1.0.0.D.
3) Included multiple security updates.
2) Updated to AGESA MilanPI 1.0.0.D.
3) Included multiple security updates.
Version : M14_R13
35.41 MB
Nov 04, 2024
1) Fixed PKfail Vulnerability.
2) Optimized BcpPro tool compatibility.
2) Optimized BcpPro tool compatibility.
Version : M13_R12
35.4 MB
Aug 26, 2024
Windows and UEFI mode flash BIOS SOP
Please download BIOS update tool from AMI Website
Please download BIOS update tool from AMI Website
-
0.31 MB
Jan 29, 2021
Warning:
更新BIOS有其潛在的風險,如果您使用目前版本的BIOS沒有問題,我們建議您不要任意更新BIOS。如需更新BIOS,請小心的執行,以避免不當的操作而造成系統毀損.
什麼是 BETA 版?
BETA版是正式推出前的試用版本。雖然該版本已經過測試,但可能還存在部份尚未發現、可能影響執行效能和功能的小問題。 請注意BETA版非正式的版本,並請密切注意正式版本的推出。
更新BIOS有其潛在的風險,如果您使用目前版本的BIOS沒有問題,我們建議您不要任意更新BIOS。如需更新BIOS,請小心的執行,以避免不當的操作而造成系統毀損.
什麼是 BETA 版?
BETA版是正式推出前的試用版本。雖然該版本已經過測試,但可能還存在部份尚未發現、可能影響執行效能和功能的小問題。 請注意BETA版非正式的版本,並請密切注意正式版本的推出。
- All
- All
- Windows Server 2022
- Windows Server 2019
- Windows Server 2016 R2 64bit
- Windows Server 2016 64bit
- Windows Server 2012 R2 64bit
- Windows Server 2012 64bit
- Windows 10 64bit
- VMware
- Ubuntu
- Linux CentOS
- Linux
工具程式
說明
版本
檔案大小
日期
GSM CLI
Version : 2.1.77
147.89 MB
Sep 27, 2024
作業系統: Windows Server 2012 64bit,Windows Server 2012 R2 64bit,Linux CentOS,Windows 10 64bit,Ubuntu,Windows Server 2016 R2 64bit,Windows Server 2019,Windows Server 2022
GSM Server
Version : 2.12
926.33 MB
Jan 18, 2023
作業系統: Linux,Windows Server 2016 64bit,Windows Server 2019
GSM Agent
Version : 2.5
720.29 MB
Dec 27, 2021
作業系統: Linux,Windows Server 2016 64bit,Windows Server 2019
Firmware
說明
版本
檔案大小
日期
BMC Firmware with embedded GIGABYTE Management Console
(AST2500 AMI)
(AST2500 AMI)
Version : 12.61.21
105.38 MB
Apr 11, 2024
英語
使用手冊
說明
版本
檔案大小
日期
說明
版本
檔案大小
日期
RESOURCES
Articles
Tech Guide | May 31, 2022
私有雲的需要與必要:如何評估企業的雲端部署
雲端運算盛行的當下,想必「私有雲」和「公有雲」對讀者來說不是第一次聽到。很有可能,在您的日常生活中,您已經受惠於這兩種雲端服務,但您真的了解兩者之間的差異嗎?如果有必要,您能幫您的工作場所建構「私有雲」嗎?技嘉科技是伺服器技術和雲端運算解決方案的知名品牌,發表本篇《科技指南》,目的是說明私有雲和公有雲的差別,並且介紹私有雲的種種優勢與限制;最後,本篇文章將推薦適合用來建造私有雲的技嘉科技伺服器產品,讓您有機會享用專屬於您的私有雲。
Video
Video | July 28, 2021
Heroes Ascension
Over the past year or so, due to global warming and climate changes, all parts of the world have witnessed extreme weather events that are more severe than ...
News
Media Review
IT Creations | April 12, 2023
Review GIGABYTE S252-ZC0 Server
This is a storage server with a side-mounted storage configuration that can support up to 24x 3.5-inch storage bays in a 2U chassis, with 12 bays on each side. It’s like a magic act! The drive cages are only accessible when you pull the server out of the enclosure. With support from dual AMDs 3rd generation 7003 series EPYC Milan processors, this system can provide up to 64x cores per socket for up to 128 physical cores and 256 virtual threads. As a storage server, it is designed for Software Defined Storage (SDS), Big Data, use as a…
Others
Back to S252-ZC0