H274-S61- LAW1

High Density Server - Intel® Xeon® 6 Processors - 2U 4-Node DP 8-Bay Gen5 NVMe/SATA/SAS-4 DLC
  • Direct liquid cooling solution
  • 2U 4-node rear access server system
  • Dual Intel® Xeon® 6 Processors per node, LGA 4710
  • 8-Channel DDR5 RDIMM / MCR DIMM, 16 x DIMMs per node
  • Dual ROM Architecture
  • 8 x 1Gb/s LAN ports via Intel® I350-AM2
  • 8 x 2.5" Gen5 NVMe/SATA/SAS-4 hot-swappable bays
  • 4 x M.2 slots with PCIe Gen4 x4 interface (optional)
  • 4 x LP PCIe Gen5 x16 slots
  • 4 x OCP 3.0 Gen5 x16 slots
  • Dual 3000W 80 PLUS Titanium redundant power supply
Get a Quote
* The entire materials provided herein are for reference only. GIGABYTE reserves the right to modify or revise the content at anytime without prior notice.
* Advertised performance is based on maximum theoretical interface values from respective Chipset vendors or organization who defined the interface specification. Actual performance may vary by system configuration.
* All trademarks and logos are the properties of their respective holders.
* Due to standard PC architecture, a certain amount of memory is reserved for system usage and therefore the actual memory size is less than the stated amount.

SPECIFICATIONS

Dimensions (WxHxD, mm)
2U 4-Node - Rear access
440 x 87.5 x 877
Motherboard
MS64-HD0
CPU
Intel® Xeon® 6 Processors
- Intel® Xeon® 6700E-Series Processors
- Intel® Xeon® 6700P-Series Processors (available Q1'25)
- Intel® Xeon® 6500P-Series Processors (available Q1'25)

Dual processor per node, TDP up to 350W

Note: If only 1 CPU is installed, some PCIe or memory functions might be unavailable.
Socket
Per Node:
2 x LGA 4710

Total:
8 x LGA 4710

Socket E2
Chipset
System on Chip
Memory
Per node:
16 x DIMM slots

Total:
64 x DIMM slots

DDR5 memory supported
MCR DIMM supported*
8-Channel memory architecture
RDIMM: Up to 6400 MT/s
MCR DIMM: Up to 8000 MT/s

*MCR DIMMs are only supported with Intel® Xeon® 6 Processors with P-cores.
LAN
Per node:
On I/O board:
- 2 x 1Gb/s LAN ports (1 x Intel® I350-AM2)
- Support NCSI function
- 1 x 10/100/1000 Mbps Management LAN

Total:
On I/O boards:
- 8 x 1Gb/s LAN ports (4 x Intel® I350-AM2)
- Support NCSI function
- 4 x 10/100/1000 Mbps Management LAN

Note: Spanning Tree Protocol (STP) must be enabled on LAN switches when using a ring topology.
Video
Integrated in Aspeed® AST2600
2D Video Graphic Adapter with PCIe bus interface
1920x1200@60Hz 32bpp

Management chip on CMC board:
Integrated in Aspeed® AST2620
Storage
Per node:
2 x 2.5" Gen5 NVMe/SATA/SAS-4* hot-swappable bays
- (NVMe & SATA from CPU_1)

Total:
8 x 2.5" Gen5 NVMe/SATA/SAS-4* hot-swappable bays
- (NVMe & SATA from CPU_1)

*SAS card is required to support SAS drives.
SAS
Require SAS add-in cards
RAID
Require RAID add-in cards
Expansion Slots
Per node:
Riser Card CRSH01R:
- 1 x PCIe x16 (Gen5 x16) low-profile slot, from CPU_0

1 x OCP 3.0 slot with PCIe Gen5 x16 bandwidth, from CPU_0
Supports NCSI function

Optional 1 x M.2 slot (CMTP160):
- M-key
- PCIe Gen4 x4, from CPU_1
- Supports 2260/2280/22110 cards

Total:
Riser Card CRSH01R x 4:
- 4 x PCIe x16 (Gen5 x16) low-profile slots, from CPU_0

4 x OCP 3.0 slots with PCIe Gen5 x16 bandwidth, from CPU_0
Support NCSI function

Optional 4 x M.2 slots (CMTP160):
- M-key
- PCIe Gen4 x4, from CPU_1
- Supports 2260/2280/22110 cards
Internal I/O
Per node:
1 x TPM header
1 x PRoT connector
1 x VROC connector
Front I/O
Per node:
1 x Power button with LED
1 x ID button with LED
1 x Reset button
1 x System status LED

Total:
4 x Power buttons with LED
4 x ID buttons with LED
4 x Reset buttons
4 x System status LEDs
*1 x CMC status LED
*1 x CMC reset button

*Only one CMC status LED and reset button per system.
Rear I/O
Per node:
2 x USB 3.2 Gen1
1 x Mini-DP
2 x RJ45
1 x MLAN
1 x System status LED

Total:
8 x USB 3.2 Gen1
4 x Mini-DP
8 x RJ45
4 x MLAN
4 x System status LEDs
Backplane Board
Speed and bandwidth:
PCIe Gen5 x4 or SATA 6Gb/s or SAS-4 24Gb/s
Security Modules
1 x TPM header with SPI interface per node
- Optional TPM2.0 kit: CTM012

1 x PRoT module connector (M.2 M-key) per node
- Optional PRoT module (AST1060 solution): CSC1200
Power Supply
Dual 3000W 80 PLUS Titanium redundant power supply

AC Input:
- 100-127V~/ 16A, 50/60Hz
- 200-207V~/ 16A, 50/60Hz
- 208-240V~/ 16A, 50/60Hz

DC Input: (Only for China)
- 240Vdc/ 16A

DC Output:
- Max 1200W/ 100-127V~
+12.2V/ 98.36A
+12.2Vsb/ 3A
- Max 2600W/ 200-207V~
+12.2V/ 213A
+12.2Vsb/ 3A
- Max 3000W/ 208-240V~ or 240Vdc Input
+12.2V/ 245.9A
+12.2Vsb/ 3A

Note: The system power supply requires C19 power cord.
System Management
Aspeed® AST2600 management controller
GIGABYTE Management Console (AMI MegaRAC SP-X) web interface

  • Dashboard
  • HTML5 KVM
  • Sensor Monitor (Voltage, RPM, Temperature, CPU Status …etc.)
  • Sensor Reading History Data
  • FRU Information
  • SEL Log in Linear Storage / Circular Storage Policy
  • Hardware Inventory
  • Fan Profile
  • System Firewall
  • Power Consumption
  • Power Control
  • Advanced power capping
  • LDAP / AD / RADIUS Support
  • Backup & Restore Configuration
  • Remote BIOS/BMC/CPLD Update
  • Event Log Filter
  • User Management
  • Media Redirection Settings
  • PAM Order Settings
  • SSL Settings
  • SMTP Settings
OS Compatibility
Please refer to OS compatibility table in support page
System Fans
4 x 80x80x80mm (16,500rpm)
Operating Properties
Operating temperature: 10°C to 40°C
Operating humidity: 8-80% (non-condensing)
Non-operating temperature: -40°C to 60°C
Non-operating humidity: 20%-95% (non-condensing)

Note:
1) The ambient temperature and relative humidity of the environment depend on the inlet supply water temperature and the coolant flow rate.
2) If the relative humidity surpasses 60%, maintain the inlet water temperature between 40°C and 45°C to prevent condensation and ensure optimal system performance.
Packaging Dimensions
w/ cold plate loops: 1185 x 705 x 409 mm
w/o cold plate loops: 1176 x 709 x 322 mm
Packaging Content
1 x H274-S61-LAW1
8 x CoolIT CPU cold plate loops
16 x Carriers
1 x 3-Section Rail kit
Part Numbers
- Barebone w/ cold plates: 6NH274S61DR000LAW1*
- Barebone w/o cold plates: 6NH274S61DZ000LAW1*
- Motherboard: 9MS64HD0UR-000
- 3-Section Rail kit: 25HB2-A66125-K0R
- CoolIT CPU cold plate loop: 25ST7-10000E-C4R
- Front panel board - CFPH004: 9CFPH004NR-00
- Backplane board - CBPH081: 9CBPH081NR-00
- Fan module: 25ST2-888020-S1R
- Riser card - CRSH01R: 9CRSH01RNR-00
- I/O board - CLBH160: 9CLBH160NR-00
- Power supply: 25EP0-23000V-L0S

Optional parts:

- C19 power cord 125V/15A (US): 25CP1-018000-Q0R
- C19 power cord 250V/16A (EU): 25CP3-01830H-Q0R
- C19 power cord 125V/15A (JP): 25CPA-01830B-Q0R
- M.2 riser card - CMTP160: 9CMTP160NR-00
- CoolIT leak sensor board: 6NH274S60S1000LAW10 (QPA:4)
* The entire materials provided herein are for reference only. GIGABYTE reserves the right to modify or revise the content at anytime without prior notice.
* Advertised performance is based on maximum theoretical interface values from respective Chipset vendors or organization who defined the interface specification. Actual performance may vary by system configuration.
* All trademarks and logos are the properties of their respective holders.
* Due to standard PC architecture, a certain amount of memory is reserved for system usage and therefore the actual memory size is less than the stated amount.

SUPPORT

  • All
  • All
  • Windows Server 2022
  • Windows Server 2019
  • Windows Server 2016 R2 64bit
  • Windows Server 2016 64bit
  • Windows Server 2012 R2 64bit
  • Windows Server 2012 64bit
  • Windows 10 64bit
  • VMware
  • Ubuntu
  • Linux CentOS
  • Linux
Tiện ích
Mô tả
Phiên bản
Kích cở
Ngày
GSM CLI
Version : 2.1.76
147.87 MB
May 22, 2024
OS: Windows Server 2012 64bit,Windows Server 2012 R2 64bit,Linux CentOS,Windows 10 64bit,Ubuntu,Windows Server 2016 R2 64bit,Windows Server 2019,Windows Server 2022
Hướng dẫn
Mô tả
Phiên bản
Kích cở
Ngày

RESOURCES

Back to H274-S61-LAW1
{{ selectedProductCount }}
Compare
  • {{ selectedProducts[index].modelName }}
Clear All
Trở về
You may only add up to 4 items for comparison at one time.