- Home
- Enterprise
- High Density Servers
- H263-S63-AAN1
H263-S63- AAN1
- 2U 4-node rear access server system
- Dual 5th/4th Gen Intel® Xeon® Scalable Processors per node
- 8-Channel DDR5 RDIMM, 16 x DIMMs per node
- Dual ROM Architecture
- 1 x CMC port
- 8 x 2.5" Gen4 NVMe/SATA/SAS hot-swap bays
- 4 x M.2 slots with PCIe Gen4 x4 interface (optional)
- 8 x LP PCIe Gen5 x16 slots
- 4 x LP PCIe Gen5 x16 slots (optional)
- 4 x OCP NIC 3.0 PCIe Gen5 x16 slots
- Dual 2600W 80 PLUS Titanium redundant power supply
* 모든 상표와 로고는 해당 소유자의 자산입니다.
* PC의 표준 아키텍쳐에 의해, 메모리의 특정 부분이 시스템에 사용되어 실제 메모리 크기는 표준보다 적게 표시될 수 있습니다.
SPECIFICATIONS
440 x 87.5 x 840
4th Generation Intel® Xeon® Scalable Processors
Dual processor per node, TDP up to 225W
- With 1 x LP and no OCP card at 30°C ambient, TDP up to 270W
- With 2 x LP and no OCP card at 25°C ambient, TDP up to 270W
[Note] If only 1 CPU is installed, some PCIe or memory functions might be unavailable.
Socket E
DDR5 memory supported
8-Channel memory architecture
5th Gen Intel® Xeon®:
RDIMM: Up to 5600 MT/s
4th Gen Intel® Xeon®:
RDIMM: Up to 4800 MT/s
4 x 10/100/1000 Mbps Management LAN
1 x CMC Management LAN [1]
[1] Please refer to optional parts for ring topology support.
[Note] Spanning Tree Protocol (STP) must be enabled on LAN switches when using a ring topology.
- 4 x VGA ports
8 x 2.5" Gen4 NVMe/SATA/SAS [1]
- (NVMe from CPU_1)
Optional internal M.2 (CMTP061 x 4):
4 x M.2 (2280/22110), PCIe Gen4 x4, from CPU_1
[1] SAS card is required to support SAS drives.
Onboard VROC key header
Support optional RAID add-in cards
- 4 x LP x16 (Gen5 x16), from CPU_0
Riser Card CRSH01U x 4:
- 4 x LP x16 (Gen5 x16), from CPU_0
Optional Riser Card CRSH310 x 4:
- 4 x LP x16 (Gen5 x16), from CPU_1
4 x OCP NIC 3.0 (Gen5 x16), from CPU_0
- Support NCSI function
4 x ID buttons with LED
4 x Reset buttons
4 x System status LEDs
1 x CMC status LED
1 x CMC reset button
4 x VGA ports
4 x MLAN ports
4 x ID buttons with LED
1 x CMC port
PCIe Gen4 x4 or SATA 6Gb/s or SAS 12Gb/s
- Optional TPM2.0 kit: CTM010
Available for 2+1 redundant power supply configuration (optional)
AC Input:
- 100-127V~/ 15A, 50-60Hz
- 200-240V~/ 15A, 50-60Hz
DC Input: (Only for China)
- 240Vdc/ 15A
DC Output:
- Max 1000W/ 100-127V~
+12.2V/ 82A
+12.2Vsb/ 4.5A
- Max 2600W/ 200-240V~ or 240Vdc Input
+12.2V/ 213A
+12.2Vsb/ 4.5A
[1] The system power supply requires C19 power cord.
Aspeed® AST2520 Chassis Management Controller
GIGABYTE Management Console web interface
- Dashboard
- HTML5 KVM
- Sensor Monitor (Voltage, RPM, Temperature, CPU Status …etc.)
- Sensor Reading History Data
- FRU Information
- SEL Log in Linear Storage / Circular Storage Policy
- Hardware Inventory
- Fan Profile
- System Firewall
- Power Consumption
- Power Control
- Advanced power capping
- LDAP / AD / RADIUS Support
- Backup & Restore Configuration
- Remote BIOS/BMC/CPLD Update
- Event Log Filter
- User Management
- Media Redirection Settings
- PAM Order Settings
- SSL Settings
- SMTP Settings
Additional certifications:
Windows Server 2022
Operating humidity: 8-80% (non-condensing)
Non-operating temperature: -40°C to 60°C
Non-operating humidity: 20%-95% (non-condensing)
8 x CPU heatsinks
24 x Carriers
1 x 3-Section Rail kit
- Barebone package (4th Gen): 6NH263S63DR000AAN1*
- Motherboard: 9MS63HD1UR-000*
- 3-Section Rail kit: 25HB2-A66125-K0R
- CPU heatsink: 25ST1-453207-C1R/25ST1-453208-C1R
- Front panel board - CFPH004: 9CFPH004NR-00*
- Backplane board - CBPH081: 9CBPH081NR-00*
- Fan module: 25ST2-88382P-S1R/25ST2-88382Q-S1R
- Riser card - CRSH01T: 9CRSH01TNR-00*
- Riser card - CRSH01U: 9CRSH01UNR-00*
- LAN board - CLBH010: 9CLBH010NR-00*
- Power supply: 25EP0-226001-G1S
Optional parts:
- C19 power cord 125V/15A (US): 25CP1-018000-Q0R
- C19 power cord 250V/16A (EU): 25CP3-01830H-Q0R
- C19 power cord 125V/15A (JP): 25CPA-01830B-Q0R
- M.2 riser card - CMTP061: 9CMTP061NR-00*
- Riser card - CRSH310: 9CRSH310NR-00*
- Ring topology kit (10-kit package): 6NH263S62S1000AAN11
- RMA packaging: 6NH263S63SR-RMA-A100
* 모든 상표와 로고는 해당 소유자의 자산입니다.
* PC의 표준 아키텍쳐에 의해, 메모리의 특정 부분이 시스템에 사용되어 실제 메모리 크기는 표준보다 적게 표시될 수 있습니다.
SUPPORT
- All
- All
- Windows Server 2022
- Windows Server 2019
- Linux
Intel® SATA RAID and Utility
1. Updates RC 113.D55 (EagleStream uPLR3 BKC 2024 WW37).
2. Updates EMR Microcode:
EMR Production A*/R* Step:
m_87_c06f2_21000291.pdb
3. Updates SPR Microcode:
SPR Production E*/S* Step:
m_87_806f8_2b000620.pdb
SPR HBM Production B* Step:
m_10_806f8_2c0003e0.pdb
4. Includes security updates for
CVE-2024-21781, CVE-2024-21820,
CVE-2024-21829, CVE-2024-21850,
CVE-2024-21853, CVE-2024-21859,
CVE-2024-22185, CVE-2024-23599,
CVE-2024-23918, CVE-2024-23984,
CVE-2024-24968, CVE-2024-24985,
CVE-2024-25565, CVE-2024-25571,
CVE-2024-26021, CVE-2024-27457,
CVE-2024-28047, CVE-2024-30211,
CVE-2024-31068, CVE-2024-31155,
CVE-2024-31157, CVE-2024-33607,
CVE-2024-36242, CVE-2024-37020,
CVE-2024-39279.
Windows and UEFI mode flash BIOS SOP
Please download BIOS update tool from AMI Website
BIOS 플래시는 잠재적인 위험요소가 있기 때문에 현재 버전의 BIOS를 사용하는 동안 문제가 발생하지 않았다면 BIOS를 플래시하지 않는 것을 권장합니다. BIOS를 플래시하려면 조심해야 하며 부적절한 BIOS 플래시는 시스템에 고장을 일으킬 수 있습니다.
What is a BETA?
BETA는 최종 제품의 기능 중 일부는 포함되지 않을 수도 있습니다. BETA 서비스 동안에 제품의 새로운 특징을 미리 살펴볼 수 있으며 기가바이트의 제품을 최대한 경험할 수 있습니다.
- All
- All
- Windows Server 2022
- Windows Server 2019
- Windows Server 2016 R2 64bit
- Windows Server 2016 64bit
- Windows Server 2012 R2 64bit
- Windows Server 2012 64bit
- Windows 10 64bit
- VMware
- Ubuntu
- Linux CentOS
- Linux
BMC firmware with embedded GIGABYTE Management Console (AST2600)
GCT Diagnostic Analyzer
Note: Please make sure the system CMC firmware version is 12.40.19 or later before updating BMC firmware
5th Generation Intel® Xeon® Scalable Processors
Intel® Xeon® CPU Max Series