H281-PE0

High Density Server - 2nd/1st Gen Intel® Xeon® Scalable - 2U 4-Node DP 8-Bay SATA/SAS
  • Supports 5G network infrastructure
  • 2U 4-node front access server system
  • Dual 2nd/1st Gen Intel® Xeon® Scalable Processors per node
  • 6-Channel DDR4 RDIMM/LRDIMM, 96 x DIMMs
  • Supports Intel® Optane™ DC Persistent Memory
  • 8 x 10Gb/s LAN ports via Intel® X550-BT2
  • 1 x CMC port
  • 8 x 2.5" SATA/SAS hot-swappable bays
  • 4 x M.2 slots with PCIe Gen3 x4 interface
  • 4 x LP PCIe Gen3 x16 slots on the front side
  • 8 x LP PCIe Gen3 x16 slots on the rear side
  • 4 x OCP Gen3 x16 mezzanine slots
  • Dual 2200W 80 PLUS Platinum redundant power supply
  • Optimized performance with Mellanox Infiniband EDR 100G or Ethernet 100G products
Get a Quote
* Les informations ici proposées le sont pour référence uniquement. GIGABYTE se réserve le droit de modifier ce contenu à tout moment et sans préavis.
* Marques et logos appartiennent aux détenteurs respectifs de leurs droits.
* L'architecture de grand nombre de PC affectera directement la capacité mémoire, en effet, une certaine quantité de RAM sera affectée au système, la quantité totale affichée pourra alors varier de celle insérée sur votre carte mère

SPECIFICATIONS

Dimensions (WxHxD, mm)
2U 4-Node - Front access
447 x 87 x 902.3
Motherboard
MH81-LM0
CPU
2nd Generation Intel® Xeon® Scalable Processors
Intel® Xeon® Scalable Processors
Dual processor per node, TDP up to 165W

Note: If only 1 CPU is installed, some PCIe or memory functions might be unavailable.
Socket
Per Node:
2 x LGA 3647

Total:
8 x LGA 3647

Socket P
Chipset
Intel® C621
Memory
Per node:
24 x DIMM slots

Total:
96 x DIMM slots

DDR4 memory supported only
6-channel memory architecture
RDIMM up to 64GB supported
LRDIMM up to 128GB supported
Supports Intel® Optane™ DC Persistent Memory (DCPMM)
1.2V modules: 2933/2666/2400/2133 MT/s

Note:
1. 2933 MT/s for 2nd Generation Intel® Xeon® Scalable Processors only.
2. Intel® Optane™ DC Persistent Memory for 2nd Generation Intel® Xeon® Scalable Processors only.
LAN
Per node:
2 x 10Gb/s LAN ports (1 x Intel® X550-BT2)
Support NCSI function

1 x 10/100/1000 Mbps Management port

Total:
8 x 10Gb/s LAN ports (4 x Intel® X550-BT2)
Support NCSI function

4 x 10/100/1000 Mbps Management ports
1 x 10/100/1000 Mbps CMC port
Video
Integrated in Aspeed® AST2500 x 4
- 4 x VGA ports
Storage
Per node:
2 x 2.5" 7mm SATA/SAS hot-swappable bays

Total:
8 x 2.5" 7mm SATA/SAS hot-swappable bays

SAS card is required for SAS devices support
RAID
Intel® SATA RAID 0/1
Expansion Slots
Per node:
1 x PCIe x16 (Gen3 x16) low-profile slot on the front side
2 x PCIe x16 (Gen3 x16) low-profile slots on the rear side

1 x OCP mezzanine slot with PCIe Gen3 x16 bandwidth

1 x M.2 slot:
- M-key
- PCIe Gen3 x4, from CPU_0
- Supports 2280 cards

Total:
4 x PCIe x16 (Gen3 x16) low-profile slots on the front side
8 x PCIe x16 (Gen3 x16) low-profile slots on the rear side

4 x OCP mezzanine slots with PCIe Gen3 x16 bandwidth

4 x M.2 slots:
- M-key
- PCIe Gen3 x4, from CPU_0
- Supports 2280 cards
Internal I/O
Per node:
1 x TPM header
Front I/O
Per node:
2 x USB 3.0
1 x VGA
2 x RJ45
1 x MLAN
1 x Power button with LED
1 x ID button with LED
1 x NMI button
1 x Reset button
1 x System status LED

Total:
8 x USB 3.0
4 x VGA
8 x RJ45
4 x MLAN
4 x Power buttons with LED
4 x ID buttons with LED
4 x NMI buttons
4 x Reset buttons
4 x System status LEDs
Rear I/O
CMC module:
1 x MLAN
1 x MLAN Cascade Port
1 x Status LED
1 x Power on LED

Expansion module:
1 x Power on LED
Backplane Board
Speed and bandwidth:
SATA 6Gb/s or SAS 12Gb/s
TPM
1 x TPM header with SPI interface
- Optional TPM2.0 kit: CTM010
Power Supply
Dual 2200W 80 PLUS Platinum redundant power supply

AC Input:
- 100-127V~/ 14A, 47-63Hz
- 200-240V~/ 12.6A, 47-63Hz

DC Input: (Only for China)
- 240Vdc/ 12.6A

DC Output:
- Max 1200W/ 100-127V~
+12.12V/ 95.6A
+12Vsb/ 3.5A
- Max 2200W/ 200-240V~ or 240Vdc Input
+12.12V/ 178.1A
+12Vsb/ 3.5A

Note:
1) The system power supply requires C19 power cord.
2) 2000W 80 PLUS Titanium power supply as an option.
System Management
Aspeed® AST2500 Baseboard Management Controller
Aspeed® AST1250 Chassis Management Controller
Avocent® MergePoint IPMI 2.0 web interface:
  • Network settings
  • Network security settings
  • Hardware information
  • Users control
  • Services settings
  • IPMI settings
  • Sessions control
  • LDAP settings
  • Power control
  • Fan profiles
  • Voltages, fans and temperatures monitoring
  • System event log
  • Events management (platform events, trap settings, email settings)
  • Serial Over LAN
  • vKVM & vMedia (HTML5)
OS Compatibility
For Skylake processors:

Citrix Xenserver 7.1.0 CU2 or later
Citrix Xenserver 7.4.0 or later
Citrix Hypervisor 8.0.0 or later

Red Hat Enterprise Linux 6.9 or later
Red Hat Enterprise Linux 7.3 or later
Red Hat Enterprise Linux 8.0 or later
Red Hat Enterprise Linux 9.0 or later

SUSE Linux Enterprise Server 11 SP4 or later
SUSE Linux Enterprise Server 12 SP2 or later
SUSE Linux Enterprise Server 15 or later

Ubuntu 16.04.1 LTS or later
Ubuntu 18.04 LTS or later
Ubuntu 20.04 LTS or later

VMware ESXi 6.0 Update3 or later
VMware ESXi 6.5 or later
VMware ESXi 6.7 or later
VMware ESXi 7.0 or later
VMware ESXi 8.0 or later

Windows Server 2012 R2 with Update
Windows Server 2016
Windows Server 2019

For Cascade Lake processors:

Citrix Xenserver 7.1.0 CU2 or later
Citrix Xenserver 7.5.0 or later
Citrix Hypervisor 8.0.0 or later

Red Hat Enterprise Linux 7.6 or later
Red Hat Enterprise Linux 8.0 or later
Red Hat Enterprise Linux 9.0 or later

SUSE Linux Enterprise Server 12 SP3 or later
SUSE Linux Enterprise Server 15 or later

Ubuntu 18.04 LTS or later
Ubuntu 20.04 LTS or later
Ubuntu 22.04 LTS or later

VMware ESXi 6.0 Update3 or later
VMware ESXi 6.5 Update2 or later
VMware ESXi 6.7 Update1 or later
VMware ESXi 7.0 or later
VMware ESXi 8.0 or later

Windows Server 2012 R2 with Update
Windows Server 2016
Windows Server 2019
System Fans
10 x 60x60x38mm (21,700rpm)
Operating Properties
Operating temperature: 10°C to 35°C
Operating humidity: 8-80% (non-condensing)
Non-operating temperature: -40°C to 60°C
Non-operating humidity: 20%-95% (non-condensing)
Weight
L6 system: 31.5kg
Packaging Dimensions
1167 x 770 x 280 mm
Packaging Content
1 x H281-PE0
8 x CPU heatsinks
1 x Rail kit
8 x Non-Fabric CPU carriers
Part Numbers
- Barebone package: 6NH281PE0MR-00*
- Motherboard: 9MH81LM0NR-00
- System transfer board: 9CNBH07NR-00
- Backplane board - CBPH020: 9CBPH020NR-00
- CMC board: 9CMBH20NR-00
- Riser card - CRSH012: 9CRSH012NR-00
- Tool-less rail kit: 25HB2-A86102-K0R
- CPU heatsink 1: 25ST1-253206-C1R
- CPU heatsink 2: 25ST1-253207-C1R
- 7mm HDD/SSD tray: 25EK3-H28100-U0R
- Fan module: 25ST2-663821-S0S
- Power supply: 25EP0-222001-D0S

Optional parts:

- C19 power cord 125V/15A (US): 25CP1-018000-Q0R
- C19 power cord 250V/16A (EU): 25CP3-01830H-Q0R
- C19 power cord 250V/15A (US): 25CP1-018300-Q0R
* Les informations ici proposées le sont pour référence uniquement. GIGABYTE se réserve le droit de modifier ce contenu à tout moment et sans préavis.
*Les performances affichées sont basées sur les informations proposées par les constructeurs de chipsets ou sociétés définissant les caractéristiques des interfaces. Performances pouvant varier selon configuration.
* Marques et logos appartiennent aux détenteurs respectifs de leurs droits.
* L'architecture de grand nombre de PC affectera directement la capacité mémoire, en effet, une certaine quantité de RAM sera affectée au système, la quantité totale affichée pourra alors varier de celle insérée sur votre carte mère

SUPPORT

  • All
  • All
  • Windows Server 2019
  • Windows Server 2016 64bit
  • Windows Server 2012 R2 64bit
  • Linux
LAN
LAN
Version
Taille
Date
SATA RAID
SATA RAID
Version
Taille
Date
Intel® SATA Preinstall driver
(For AHCI / RAID Mode)
Note: Windows setup to read from USB devices
Version : 6.0.0.1357
6.54 MB
Apr 19, 2019
OS: Windows Server 2012 R2 64bit,Windows Server 2016 64bit,Windows Server 2019
Intel® Rapid Storage Technology enterprise (Intel® RSTe)
Version : 6.0.0.1357
265.09 MB
Apr 21, 2019
OS: Windows Server 2012 R2 64bit,Windows Server 2016 64bit,Windows Server 2019
Warning:
Because BIOS flashing is potentially risky, if you do not encounter problems using the current version of BIOS, it is recommended that you not flash the BIOS. To flash the BIOS, do it with caution. Inadequate BIOS flashing may result in system malfunction.

What is a BETA?
BETA describes a new version that is reliable yet may not include all the features of the final product. During this phase we are previewing new features and gathering customer input to insure our product provides the best experience possible.

Update CPU ID/Micro codes in new BIOS means?
[1] To support new series of CPUs, or [2] To support the same CPU but with new stepping. CPU support of motherboard is consist of BIOS and hardware design, detail CPU support information please see CPU support list.
  • All
  • All
  • Windows Server 2022
  • Windows Server 2019
  • Windows Server 2016 R2 64bit
  • Windows Server 2016 64bit
  • Windows Server 2012 R2 64bit
  • Windows Server 2012 64bit
  • Windows 10 64bit
  • VMware
  • Ubuntu
  • Linux CentOS
  • Linux
Utilitaire
Description
Version
Taille
Date
GSM CLI
Version : 2.1.77
147.89 MB
Sep 27, 2024
OS: Windows Server 2012 64bit,Windows Server 2012 R2 64bit,Linux CentOS,Windows 10 64bit,Ubuntu,Windows Server 2016 R2 64bit,Windows Server 2019,Windows Server 2022
Mode d'emploi
Description
Version
Taille
Date

RESOURCES

Video
Security & Technical Advisory
Back to H281-PE0
{{ selectedProductCount }}
Compare
  • Add more
    {{ selectedProducts[index].modelName }}
Clear All
retour