R281-N40

Rack Server - 2nd/1st Gen Intel® Xeon® Scalable - 2U DP 24+2-Bay Gen3 NVMe/SATA/SAS
  • Dual 2nd/1st Gen Intel® Xeon® Scalable Processors
  • 6-Channel DDR4 RDIMM/LRDIMM, 24 x DIMMs
  • Supports Intel® Optane™ DC Persistent Memory
  • 2 x 1Gb/s LAN port via Intel® I350-AM2
  • Onboard 12Gb/s SAS expander
  • 4 x 2.5" Gen3 NVMe/SATA/SAS hot-swappable bays
  • 20 x 2.5" SATA/SAS hot-swappable bays
  • 2 x 2.5" SATA/SAS hot-swappable bays on the rear side
  • 6 x FHHL PCIe Gen3 x16 and x8 slots
  • 2 x LP PCIe Gen3 x16 and x8 slots
  • 1 x OCP Gen3 x16 mezzanine slot
  • Dual 1200W 80 PLUS Platinum redundant power supply
Get a Quote
* Das vorliegende Material dient nur zur Referenz. GIGABYTE behalt sich das Recht vor, ohne Vorwarnung Inhalte zu verandern oder zu entfernen.
* Die beworbene Leistung basiert auf den maximal theoretischen Werten der Chipsatzhersteller oder von Organisationen, die die Interface-Spezifikationen erstellt haben. Die aktuelle Performance kann je nach Systemkonfiguration variieren.
* Alle Trademarks und Logos sind Eigentum der Markeninhaber.
* Aufgrund der Standard-PC-Architektur ist ein Teil des Speichers fur die Nutzung des Systems reserviert und daher kann die aktuelle Speichergrose von der Speicherangabe abweichen.

SPECIFICATIONS

Dimensions (WxHxD, mm)
2U
438 x 87.5 x 730
Motherboard
MR91-FS0
CPU
2nd Generation Intel® Xeon® Scalable Processors
Intel® Xeon® Scalable Processors
Dual processor, TDP up to 205W

Note: If only 1 CPU is installed, some PCIe or memory functions might be unavailable.
Socket
2 x LGA 3647
Socket P
Chipset
Intel® C621
Memory
24 x DIMM slots
DDR4 memory supported only
6-channel memory architecture
RDIMM up to 64GB supported
LRDIMM up to 128GB supported
Supports Intel® Optane™ DC Persistent Memory (DCPMM)
1.2V modules: 2933/2666/2400/2133 MT/s

Maximum verified DCPMM configuration:

* Ambient temperature 35°C
* 2nd Generation Intel® Xeon® Scalable processor 205W (Max.)
* DCPMM 256GB x12 pcs

DCPMM installation locations:
DIMM_P0_(A1, B1, C1)
DIMM_P0_(D1, E1, F1)
DIMM_P1_(G1, H1, I1)
DIMM_P1_(J1, K1, L1)

Note:
1. 2933 MT/s for 2nd Generation Intel® Xeon® Scalable Processors only.
2. Intel® Optane™ DC Persistent Memory for 2nd Generation Intel® Xeon® Scalable Processors only.
3. The maximum number of DCPMM that can be installed is based on a maximum operating (ambient) temperature of 35°C.
4. To enquire about installing a greater number of DCPMM, please consult with your GIGABYTE technical or sales representative.
LAN
Rear side:
2 x 1Gb/s LAN ports (1 x Intel® I350-AM2)
Support NCSI function

1 x 10/100/1000 Mbps Management LAN
Video
Integrated in Aspeed® AST2500
- 1 x VGA port
Storage
Front side:
4 x 2.5" Gen3 NVMe/SATA/SAS hot-swappable bays, NVMe from CPU_1
20 x 2.5" SATA/SAS hot-swappable bays

Rear side:
2 x 2.5" SATA/SAS hot-swappable bays

LSI SAS35x36 expander
Bandwidth: SATA 6Gb/s or SAS 12Gb/s per port

Default configuration supports:
4 x NVMe, 0 x SAS/SATA drives

SAS card is required to enable the drives
SATA
2 x 7-pin SATA III 6Gb/s with SATA DOM supported
By using pin_8 or external cable for power function
SAS
Supported via add-in SAS cards
RAID
For SATA/SAS drives:
Depends on RAID card

For NVMe drives:
Optional Intel® Virtual RAID On CPU (VROC) RAID 0/1/5

Note: VROC module is compatible for Intel®SSD only.
Expansion Slots
Riser Card CRS2131:
- 1 x PCIe x16 (Gen3 x16 or x8) FHHL slot, from CPU_0
- 1 x PCIe x8 (Gen3 x0 or x8) FHHL slot, from CPU_0
- 1 x PCIe x8 (Gen3 x8) FHHL slot, from CPU_0

Riser Card CRS2132:
- 1 x PCIe x16 (Gen3 x16 or x8) FHHL slot, from CPU_1
- 1 x PCIe x8 (Gen3 x0 or x8) FHHL slot, from CPU_1
- 1 x PCIe x8 (Gen3 x8) FHHL slot, from CPU_0

Riser Card CRS2124:
- 1 x PCIe x8 (Gen3 x0 or x8) low-profile slot, from CPU_1
- 1 x PCIe x16 (Gen3 x16 or x8) low-profile slot, from CPU_1

1 x OCP mezzanine slot with PCIe Gen3 x16 bandwidth (Type1, P1, P2, P3, P4, K2, K3), from CPU_0
1 x OCP mezzanine slot with PCIe Gen3 x16 bandwidth (Type1, P1, P2, P3, P4, K2, K3), from CPU_0, occupied by CNVO124 - 4 x NVMe mezzanine card
Internal I/O
2 x Power supply connectors
4 x SlimSAS connectors
2 x SATA 7-pin connectors
2 x CPU fan headers
1 x USB 3.0 header
1 x TPM header
1 x VROC connector
1 x Front panel header
1 x Backplane board header
1 x IPMB connector
1 x Clear CMOS jumper
1 x BIOS recovery jumper
Front I/O
2 x USB 3.0
1 x Power button with LED
1 x ID button with LED
1 x NMI button
1 x Reset button
2 x LAN activity LEDs
1 x Storage activity LED
1 x System status LED
Rear I/O
2 x USB 3.0
1 x VGA
1 x COM (RJ45)
2 x RJ45
1 x MLAN
1 x ID button with LED
Backplane Board
Speed and bandwidth:
Front side - CBP20O2: PCIe Gen3 x4
Rear side - CBP2020: SATA 6Gb/s or SAS 12Gb/s
TPM
1 x TPM header with LPC interface
- Optional TPM2.0 kit: CTM000
Power Supply
Dual 1200W 80 PLUS Platinum redundant power supply

AC Input:
- 100-240V~/ 12-7A, 50-60Hz

DC Input: (Only for China)
- 240Vdc/ 6A

DC Output:
- Max 1000W/ 100-240V~
+12V/ 80.5A
+12Vsb/ 3A
- Max 1200W/ 200-240V~ or 240Vdc Input
+12V/ 97A
+12Vsb/ 3A
System Management
Aspeed® AST2500 Baseboard Management Controller
Avocent® MergePoint IPMI 2.0 web interface:
  • Network settings
  • Network security settings
  • Hardware information
  • Users control
  • Services settings
  • IPMI settings
  • Sessions control
  • LDAP settings
  • Power control
  • Fan profiles
  • Voltages, fans and temperatures monitoring
  • System event log
  • Events management (platform events, trap settings, email settings)
  • Serial Over LAN
  • vKVM & vMedia (HTML5)
OS Compatibility
For Skylake processors:

Citrix Xenserver 7.1.0 CU2 or later
Citrix Xenserver 7.4.0 or later
Citrix Hypervisor 8.0.0 or later

Red Hat Enterprise Linux 6.9 or later
Red Hat Enterprise Linux 7.3 or later
Red Hat Enterprise Linux 8.0 or later
Red Hat Enterprise Linux 9.0 or later

SUSE Linux Enterprise Server 11 SP4 or later
SUSE Linux Enterprise Server 12 SP2 or later
SUSE Linux Enterprise Server 15 or later

Ubuntu 16.04.1 LTS or later
Ubuntu 18.04 LTS or later
Ubuntu 20.04 LTS or later

VMware ESXi 6.0 Update3 or later
VMware ESXi 6.5 or later
VMware ESXi 6.7 or later
VMware ESXi 7.0 or later
VMware ESXi 8.0 or later

Windows Server 2012 R2 with Update
Windows Server 2016
Windows Server 2019

For Cascade Lake processors:

Citrix Xenserver 7.1.0 CU2 or later
Citrix Xenserver 7.5.0 or later
Citrix Hypervisor 8.0.0 or later

Red Hat Enterprise Linux 7.6 or later
Red Hat Enterprise Linux 8.0 or later
Red Hat Enterprise Linux 9.0 or later

SUSE Linux Enterprise Server 12 SP3 or later
SUSE Linux Enterprise Server 15 or later

Ubuntu 18.04 LTS or later
Ubuntu 20.04 LTS or later
Ubuntu 22.04 LTS or later

VMware ESXi 6.0 Update3 or later
VMware ESXi 6.5 Update2 or later
VMware ESXi 6.7 Update1 or later
VMware ESXi 7.0 or later
VMware ESXi 8.0 or later

Windows Server 2012 R2 with Update
Windows Server 2016
Windows Server 2019
System Fans
4 x 80x80x38mm (16,300rpm)
Operating Properties
Operating temperature: 10°C to 35°C
Operating humidity: 8-80% (non-condensing)
Non-operating temperature: -40°C to 60°C
Non-operating humidity: 20%-95% (non-condensing)
Weight
20 kg
Packaging Dimensions
982 x 588 x 268 mm
Packaging Content
1 x R281-N40
2 x CPU heatsinks
1 x 2-Section Rail kit
2 x Non-fabric CPU carriers
Part Numbers
- Barebone package: 6NR281N40MR-00-4*
- Motherboard: 9MR91FS0NR-00
- 2-Section Rail kit: 25HB2-3A0202-K0R
- CPU heatsink: 25ST1-353105-T1R
- Non-fabric CPU carrier: 12KRC-0F3647-50R
- Front panel board - CFP2001: 9CFP2001NR-00
- Backplane board - CBP20O2: 9CBP20O2NR-00
- Backplane board - CBP2020: 9CBP2020NR-00
- Fan module: 25ST2-883829-D0R
- Riser card - CRS2124: 9CRS2124NR-00
- Riser card - CRS2131: 9CRS2131NR-00
- Riser card - CRS2132: 9CRS2132NR-00
- NVMe card - CNV0124: 9CNVO124NR-00
- Mezzanine card - CEPM080: 9CEPM080NR-00
- Power supply: 25EP0-212002-F3S
- SAS Expander module: 9CEP26O0NR-00

Optional parts:

- VROC module: 25FD0-R181N0-10R
- RJ45 type COM cable: 25CR0-200400-Y4R
* Das vorliegende Material dient nur zur Referenz. GIGABYTE behält sich das Recht vor, ohne Vorwarnung Inhalte zu verändern oder zu entfernen.
* Die beworbene Leistung basiert auf den maximal theoretischen Werten der Chipsatzhersteller oder von Organisationen, die die Interface-Spezifikationen erstellt haben. Die aktuelle Performance kann je nach Systemkonfiguration variieren.
* Alle Trademarks und Logos sind Eigentum der Markeninhaber.
* Aufgrund der Standard-PC-Architektur ist ein Teil des Speichers für die Nutzung des Systems reserviert und daher kann die aktuelle Speichergröße von der Speicherangabe abweichen.

SUPPORT

  • All
  • All
  • Windows Server 2019
  • Windows Server 2016 64bit
  • Windows Server 2012 R2 64bit
  • Linux
Chipset
Chipset
Version
Größe
Datum
LAN
LAN
Version
Größe
Datum
SATA RAID
SATA RAID
Version
Größe
Datum
Intel® SATA Preinstall driver
(For AHCI / RAID Mode)
Note: Windows setup to read from USB devices
Version : 6.0.0.1357
6.54 MB
Apr 19, 2019
Betriebssystem: Windows Server 2012 R2 64bit,Windows Server 2016 64bit,Windows Server 2019
Intel® Rapid Storage Technology enterprise (Intel® RSTe)
Version : 6.0.0.1357
265.09 MB
Apr 21, 2019
Betriebssystem: Windows Server 2012 R2 64bit,Windows Server 2016 64bit,Windows Server 2019
BIOS
Beschreibung
Version
Größe
Datum

1) Includes multiple security updates:

- CVE-2024-28047, CVE-2024-28956

- CWE-190, iSCSI Remote Memory Corruption and Dos.

- CWE-269, UEFI Variable Access - PlatformLang and Timeout.

2) Includes multiple feature updates.

Version : R29
20.56 MB
Nov 27, 2024
Warnung:
Das das Flashen des BIOS ein potentielles Risiko für den PC darstellt, empfehlen wir, das BIOS nicht zu flashen wenn der PC problemlos arbeitet. Seien Sie beim Flashen bitte vorsichtig. Ein unpassendes BIOS kann zu Systemfehlern führen.

Was ist eine BETA-Version?
BETA steht für eine neue Version, die noch in der Entwicklungsphase ist und nicht alle Funktionen der finalen Version beinhaltet. Während der Entwicklungsphase stellen wir den Usern und Kunden Vorschau-Versionen zur Verfügung, die neueste Funktionen enthalten, um die Produkte noch weiter zu verbessern..

  • All
  • All
  • Windows Server 2022
  • Windows Server 2019
  • Windows Server 2016 R2 64bit
  • Windows Server 2016 64bit
  • Windows Server 2012 R2 64bit
  • Windows Server 2012 64bit
  • Windows 10 64bit
  • VMware
  • Ubuntu
  • Linux CentOS
  • Linux
Utility
Beschreibung
Version
Größe
Datum
GSM CLI
Version : 2.1.78
147.79 MB
Dec 12, 2024
Betriebssystem: Windows Server 2012 64bit,Windows Server 2012 R2 64bit,Linux CentOS,Windows 10 64bit,Ubuntu,Windows Server 2016 R2 64bit,Windows Server 2019,Windows Server 2022
Handbuch
Beschreibung
Version
Größe
Datum

RESOURCES

Security & Technical Advisory
Back to R281-N40
{{ selectedProductCount }}
Compare
  • Add more
    {{ selectedProducts[index].modelName }}
Clear All
Zurück
You may only add up to 4 items for comparison at one time.