High Density Server - Intel® Xeon® 6 Processors - 2U 4-Node DP 8-Bay Gen5 NVMe/SATA/SAS-4 DLC
- Direct liquid cooling solution
- 2U 4-node rear access server system
- Dual Intel® Xeon® 6 Processors per node, LGA 4710
- 8-Channel DDR5 RDIMM / MCR DIMM, 16 x DIMMs per node
- Dual ROM Architecture
- 8 x 1Gb/s LAN ports via Intel® I350-AM2
- 8 x 2.5" Gen5 NVMe/SATA/SAS-4 hot-swap bays
- 4 x M.2 slots with PCIe Gen4 x4 interface (optional)
- 4 x LP PCIe Gen5 x16 slots
- 4 x OCP NIC 3.0 PCIe Gen5 x16 slots
- Dual 3000W 80 PLUS Titanium redundant power supply
* Das vorliegende Material dient nur zur Referenz. GIGABYTE behalt sich das Recht vor, ohne Vorwarnung Inhalte zu verandern oder zu entfernen.
* Die beworbene Leistung basiert auf den maximal theoretischen Werten der Chipsatzhersteller oder von Organisationen, die die Interface-Spezifikationen erstellt haben. Die aktuelle Performance kann je nach Systemkonfiguration variieren.
* Alle Trademarks und Logos sind Eigentum der Markeninhaber.
* Aufgrund der Standard-PC-Architektur ist ein Teil des Speichers fur die Nutzung des Systems reserviert und daher kann die aktuelle Speichergrose von der Speicherangabe abweichen.
* Die beworbene Leistung basiert auf den maximal theoretischen Werten der Chipsatzhersteller oder von Organisationen, die die Interface-Spezifikationen erstellt haben. Die aktuelle Performance kann je nach Systemkonfiguration variieren.
* Alle Trademarks und Logos sind Eigentum der Markeninhaber.
* Aufgrund der Standard-PC-Architektur ist ein Teil des Speichers fur die Nutzung des Systems reserviert und daher kann die aktuelle Speichergrose von der Speicherangabe abweichen.
SPECIFICATIONS
Dimensions (WxHxD, mm)
2U 4-Node - Rear access
440 x 87.5 x 877
440 x 87.5 x 877
Motherboard
MS64-HD0
CPU
Intel® Xeon® 6 Processors
- Intel® Xeon® 6700E-Series Processors
- Intel® Xeon® 6700P-Series Processors (available Q1'25)
- Intel® Xeon® 6500P-Series Processors (available Q1'25)
Dual processor per node, TDP up to 350W at 35°C ambient
[Note] If only 1 CPU is installed, some PCIe or memory functions might be unavailable.
- Intel® Xeon® 6700E-Series Processors
- Intel® Xeon® 6700P-Series Processors (available Q1'25)
- Intel® Xeon® 6500P-Series Processors (available Q1'25)
Dual processor per node, TDP up to 350W at 35°C ambient
[Note] If only 1 CPU is installed, some PCIe or memory functions might be unavailable.
Socket
8 x LGA 4710
Socket E2
Socket E2
Chipset
System on Chip
Memory
64 x DIMM slots
DDR5 memory supported
8-Channel memory architecture
MCR DIMM supported [1]
RDIMM: Up to 6400 MT/s
MCR DIMM: Up to 8000 MT/s
[1] MCR DIMMs are only supported with Intel® Xeon® 6 Processors with P-cores.
DDR5 memory supported
8-Channel memory architecture
MCR DIMM supported [1]
RDIMM: Up to 6400 MT/s
MCR DIMM: Up to 8000 MT/s
[1] MCR DIMMs are only supported with Intel® Xeon® 6 Processors with P-cores.
LAN
Rear (I/O board - CLBH160 x 4):
8 x 1Gb/s LAN (4 x Intel® I350-AM2)
- Support NCSI function
4 x 10/100/1000 Mbps Management LAN [1]
[1] Spanning Tree Protocol (STP) must be enabled on LAN switches when using a ring topology.
8 x 1Gb/s LAN (4 x Intel® I350-AM2)
- Support NCSI function
4 x 10/100/1000 Mbps Management LAN [1]
[1] Spanning Tree Protocol (STP) must be enabled on LAN switches when using a ring topology.
Video
Integrated in Aspeed® AST2600 x 4
- 4 x Mini-DP
- 4 x Mini-DP
Storage
Front hot-swap:
8 x 2.5" Gen5 NVMe/SATA/SAS-4 [1]
- (NVMe & SATA from CPU_1)
Optional internal M.2 (CMTP160 x 4):
4 x M.2 (2260/2280/22110), PCIe Gen4 x4, from CPU_1
[1] SAS card is required to support SAS drives.
8 x 2.5" Gen5 NVMe/SATA/SAS-4 [1]
- (NVMe & SATA from CPU_1)
Optional internal M.2 (CMTP160 x 4):
4 x M.2 (2260/2280/22110), PCIe Gen4 x4, from CPU_1
[1] SAS card is required to support SAS drives.
SAS
Require SAS add-in cards
RAID
Require RAID add-in cards
Onboard VROC key headers
Onboard VROC key headers
PCIe Expansion Slots
Riser Card CRSH01R x 4:
- 4 x LP x16 (Gen5 x16), from CPU_0
4 x OCP NIC 3.0 (Gen5 x16), from CPU_0
- Support NCSI function
- 4 x LP x16 (Gen5 x16), from CPU_0
4 x OCP NIC 3.0 (Gen5 x16), from CPU_0
- Support NCSI function
Front I/O
4 x Power buttons with LED
4 x ID buttons with LED
4 x Reset buttons
4 x System status LEDs
1 x CMC status LED
1 x CMC reset button
4 x ID buttons with LED
4 x Reset buttons
4 x System status LEDs
1 x CMC status LED
1 x CMC reset button
Rear I/O
I/O board - CLBH160 x 4:
8 x USB 3.2 Gen1 ports (Type-A)
4 x Mini-DP
8 x RJ45 ports
4 x MLAN ports
4 x System status LEDs
8 x USB 3.2 Gen1 ports (Type-A)
4 x Mini-DP
8 x RJ45 ports
4 x MLAN ports
4 x System status LEDs
Backplane Board
Speed and bandwidth:
PCIe Gen5 x4 or SATA 6Gb/s or SAS-4 24Gb/s
PCIe Gen5 x4 or SATA 6Gb/s or SAS-4 24Gb/s
Security Modules
4 x TPM header with SPI interface
- Optional TPM2.0 kit: CTM012
4 x PRoT connectors (only enabled on RoT SKU)
- Optional TPM2.0 kit: CTM012
4 x PRoT connectors (only enabled on RoT SKU)
Power Supply
Dual 3000W 80 PLUS Titanium redundant power supply [1]
AC Input:
- 100-127V~/ 16A, 50/60Hz
- 200-207V~/ 16A, 50/60Hz
- 208-240V~/ 16A, 50/60Hz
DC Input: (Only for China)
- 240Vdc/ 16A
DC Output:
- Max 1200W/ 100-127V~
+12.2V/ 98.36A
+12.2Vsb/ 3A
- Max 2600W/ 200-207V~
+12.2V/ 213A
+12.2Vsb/ 3A
- Max 3000W/ 208-240V~ or 240Vdc Input
+12.2V/ 245.9A
+12.2Vsb/ 3A
[1] The system power supply requires C19 power cord.
AC Input:
- 100-127V~/ 16A, 50/60Hz
- 200-207V~/ 16A, 50/60Hz
- 208-240V~/ 16A, 50/60Hz
DC Input: (Only for China)
- 240Vdc/ 16A
DC Output:
- Max 1200W/ 100-127V~
+12.2V/ 98.36A
+12.2Vsb/ 3A
- Max 2600W/ 200-207V~
+12.2V/ 213A
+12.2Vsb/ 3A
- Max 3000W/ 208-240V~ or 240Vdc Input
+12.2V/ 245.9A
+12.2Vsb/ 3A
[1] The system power supply requires C19 power cord.
System Management
Aspeed® AST2600 Baseboard Management Controller
Aspeed® AST2620 Chassis Management Controller
GIGABYTE Management Console web interface
Aspeed® AST2620 Chassis Management Controller
GIGABYTE Management Console web interface
- Dashboard
- HTML5 KVM
- Sensor Monitor (Voltage, RPM, Temperature, CPU Status …etc.)
- Sensor Reading History Data
- FRU Information
- SEL Log in Linear Storage / Circular Storage Policy
- Hardware Inventory
- Fan Profile
- System Firewall
- Power Consumption
- Power Control
- Advanced power capping
- LDAP / AD / RADIUS Support
- Backup & Restore Configuration
- Remote BIOS/BMC/CPLD Update
- Event Log Filter
- User Management
- Media Redirection Settings
- PAM Order Settings
- SSL Settings
- SMTP Settings
OS Compatibility
Please refer to OS compatibility table in support page
System Fans
4 x 80x80x80mm (16,500rpm)
Operating Properties
Operating temperature: 10°C to 35°C
Operating humidity: 8-80% (non-condensing)
Non-operating temperature: -40°C to 60°C
Non-operating humidity: 20%-95% (non-condensing)
[Note] The ambient temperature and relative humidity of the environment depend on the inlet supply water temperature and the coolant flow rate.
[Note] If the relative humidity surpasses 60%, maintain the inlet water temperature between 40°C and 45°C to prevent condensation and ensure optimal system performance.
Operating humidity: 8-80% (non-condensing)
Non-operating temperature: -40°C to 60°C
Non-operating humidity: 20%-95% (non-condensing)
[Note] The ambient temperature and relative humidity of the environment depend on the inlet supply water temperature and the coolant flow rate.
[Note] If the relative humidity surpasses 60%, maintain the inlet water temperature between 40°C and 45°C to prevent condensation and ensure optimal system performance.
Packaging Dimensions
w/ cold plate loops: 1185 x 705 x 409 mm
w/o cold plate loops: 1176 x 709 x 322 mm
w/o cold plate loops: 1176 x 709 x 322 mm
Packaging Content
1 x H274-S61-LAW1
8 x CoolIT CPU cold plate loops
1 x Mini-DP to D-Sub cable
16 x Carriers
1 x 3-Section Rail kit
8 x CoolIT CPU cold plate loops
1 x Mini-DP to D-Sub cable
16 x Carriers
1 x 3-Section Rail kit
Part Numbers
- Barebone w/ cold plates: 6NH274S61DR000LAW1*
- Barebone w/o cold plates: 6NH274S61DZ000LAW1*
- Motherboard: 9MS64HD0UR-000*
- 3-Section Rail kit: 25HB2-A66125-K0R
- CoolIT CPU cold plate loop: 25ST7-10000E-C4R
- Front panel board - CFPH004: 9CFPH004NR-00*
- Backplane board - CBPH081: 9CBPH081NR-00*
- Fan module: 25ST2-888020-S1R
- Riser card - CRSH01R: 9CRSH01RNR-00*
- I/O board - CLBH160: 9CLBH160NR-00*
- Mini-DP to D-Sub cable: 25CRN-200801-K1R
- Power supply: 25EP0-23000V-L0S
Optional parts:
- C19 power cord 125V/15A (US): 25CP1-018000-Q0R
- C19 power cord 250V/16A (EU): 25CP3-01830H-Q0R
- C19 power cord 125V/15A (JP): 25CPA-01830B-Q0R
- M.2 riser card - CMTP160: 9CMTP160NR-00*
- CoolIT leak sensor board: 6NH274S60S1000LAW10 (QPA:4)
- RMA packaging: 6NH274S61SR-RMA-L100
- Barebone w/o cold plates: 6NH274S61DZ000LAW1*
- Motherboard: 9MS64HD0UR-000*
- 3-Section Rail kit: 25HB2-A66125-K0R
- CoolIT CPU cold plate loop: 25ST7-10000E-C4R
- Front panel board - CFPH004: 9CFPH004NR-00*
- Backplane board - CBPH081: 9CBPH081NR-00*
- Fan module: 25ST2-888020-S1R
- Riser card - CRSH01R: 9CRSH01RNR-00*
- I/O board - CLBH160: 9CLBH160NR-00*
- Mini-DP to D-Sub cable: 25CRN-200801-K1R
- Power supply: 25EP0-23000V-L0S
Optional parts:
- C19 power cord 125V/15A (US): 25CP1-018000-Q0R
- C19 power cord 250V/16A (EU): 25CP3-01830H-Q0R
- C19 power cord 125V/15A (JP): 25CPA-01830B-Q0R
- M.2 riser card - CMTP160: 9CMTP160NR-00*
- CoolIT leak sensor board: 6NH274S60S1000LAW10 (QPA:4)
- RMA packaging: 6NH274S61SR-RMA-L100
* Das vorliegende Material dient nur zur Referenz. GIGABYTE behält sich das Recht vor, ohne Vorwarnung Inhalte zu verändern oder zu entfernen.
* Die beworbene Leistung basiert auf den maximal theoretischen Werten der Chipsatzhersteller oder von Organisationen, die die Interface-Spezifikationen erstellt haben. Die aktuelle Performance kann je nach Systemkonfiguration variieren.
* Alle Trademarks und Logos sind Eigentum der Markeninhaber.
* Aufgrund der Standard-PC-Architektur ist ein Teil des Speichers für die Nutzung des Systems reserviert und daher kann die aktuelle Speichergröße von der Speicherangabe abweichen.
* Die beworbene Leistung basiert auf den maximal theoretischen Werten der Chipsatzhersteller oder von Organisationen, die die Interface-Spezifikationen erstellt haben. Die aktuelle Performance kann je nach Systemkonfiguration variieren.
* Alle Trademarks und Logos sind Eigentum der Markeninhaber.
* Aufgrund der Standard-PC-Architektur ist ein Teil des Speichers für die Nutzung des Systems reserviert und daher kann die aktuelle Speichergröße von der Speicherangabe abweichen.
SUPPORT
Treiber
BIOS
Utility
Firmware
OS
- All
- All
- Windows Server 2022
- Windows Server 2019
- Linux
Chipset
Chipset
Version
Größe
Datum
Intel® Chipset Driver
Version : 10.1.19975.8620
6.41 MB
Oct 08, 2024
Betriebssystem: Windows Server 2019,Windows Server 2022
LAN
LAN
Version
Größe
Datum
Intel® LAN Driver and Utility
Version : 29.0
32.88 MB
Oct 08, 2024
Betriebssystem: Windows Server 2019,Windows Server 2022
RAID
RAID
Version
Größe
Datum
Intel® VROC
Intel® SATA RAID and Utility
Intel® SATA RAID and Utility
Version : 9.0.0.1837
101.14 MB
Oct 09, 2024
Betriebssystem: Windows Server 2019,Windows Server 2022
Utility
Utility
Version
Größe
Datum
Intel® QuickAssist Technology
Version : 2.0.w.2.2.0-0018_1
37.67 MB
Oct 09, 2024
Betriebssystem: Windows Server 2019,Windows Server 2022
BIOS
Beschreibung
Version
Größe
Datum
Include microcode update for Processor GNR R1S B0 stepping.
Version : F15
50.89 MB
Sep 09, 2024
Windows and UEFI mode flash BIOS SOP
Please download BIOS update tool from AMI Website
Please download BIOS update tool from AMI Website
-
0.31 MB
Jan 29, 2021
Warnung:
Das das Flashen des BIOS ein potentielles Risiko für den PC darstellt, empfehlen wir, das BIOS nicht zu flashen wenn der PC problemlos arbeitet. Seien Sie beim Flashen bitte vorsichtig. Ein unpassendes BIOS kann zu Systemfehlern führen.
Was ist eine BETA-Version?
BETA steht für eine neue Version, die noch in der Entwicklungsphase ist und nicht alle Funktionen der finalen Version beinhaltet. Während der Entwicklungsphase stellen wir den Usern und Kunden Vorschau-Versionen zur Verfügung, die neueste Funktionen enthalten, um die Produkte noch weiter zu verbessern..
Das das Flashen des BIOS ein potentielles Risiko für den PC darstellt, empfehlen wir, das BIOS nicht zu flashen wenn der PC problemlos arbeitet. Seien Sie beim Flashen bitte vorsichtig. Ein unpassendes BIOS kann zu Systemfehlern führen.
Was ist eine BETA-Version?
BETA steht für eine neue Version, die noch in der Entwicklungsphase ist und nicht alle Funktionen der finalen Version beinhaltet. Während der Entwicklungsphase stellen wir den Usern und Kunden Vorschau-Versionen zur Verfügung, die neueste Funktionen enthalten, um die Produkte noch weiter zu verbessern..
- All
- All
- Windows Server 2022
- Windows Server 2019
- Windows Server 2016 R2 64bit
- Windows Server 2016 64bit
- Windows Server 2012 R2 64bit
- Windows Server 2012 64bit
- Windows 10 64bit
- VMware
- Ubuntu
- Linux CentOS
- Linux
Utility
Beschreibung
Version
Größe
Datum
GSM CLI
Version : 2.1.77
147.89 MB
Sep 27, 2024
Betriebssystem: Windows Server 2012 64bit,Windows Server 2012 R2 64bit,Linux CentOS,Windows 10 64bit,Ubuntu,Windows Server 2016 R2 64bit,Windows Server 2019,Windows Server 2022
GSM Server
Version : 2.12
926.33 MB
Jan 18, 2023
Betriebssystem: Linux,Windows Server 2016 64bit,Windows Server 2019
GSM Agent
Version : 2.5
720.29 MB
Dec 27, 2021
Betriebssystem: Linux,Windows Server 2016 64bit,Windows Server 2019
BMC Restore Default Setting utility
Version : 1.0
0.15 MB
Mar 17, 2020
Betriebssystem: Ubuntu
Firmware
Beschreibung
Version
Größe
Datum
BMC firmware with embedded GIGABYTE Management Console (AST2600)
Version : 13.06.09
123.77 MB
Sep 05, 2024
English
GIGABYTE Management Console Web GUI Tool
GCT Diagnostic Analyzer
GCT Diagnostic Analyzer
Version : 1.0
2519.27 MB
Aug 15, 2024
English
Handbuch
Beschreibung
Version
Größe
Datum
User Guide - GIGABYTE Management Console (AMI AST2600)
Version : 1.0
11.72 MB
Aug 12, 2024
English
Beschreibung
Version
Größe
Datum
RESOURCES
News
Media Review
Others
Back to H274-S61-LAW1