- Home
- Enterprise
- Storage Servers
- S472-Z30
S472-Z30
Storage Server - AMD EPYC™ 7003/7002 - 4U UP 50-Bay Gen4 NVMe/SATA/SAS
- Hardware-level root of trust
- Single AMD EPYC™ 7003/7002 Series Processors (with AMD 3D V-Cache™ Technology)
- 8-Channel DDR4 RDIMM/LRDIMM, 16 x DIMMs
- 2 x 1Gb/s LAN ports via Intel® I350-AM2
- 24 x 3.5"/2.5" SATA/SAS hot-swappable bays
- 4 x 2.5" Gen4 NVMe/SATA/SAS hot-swappable bays
- 8 x 2.5" Gen4 NVMe hot-swappable bays
- 12 x 2.5" SATA/SAS hot-swappable bays
- 2 x 2.5" SATA hot-swappable bays on the rear side
- SAS expander with 12Gb/s transfer speed
- 2 x M.2 slots with PCIe Gen4 x4 interface
- 2 x LP PCIe Gen4 x16 and x8 slots
- Up to 2 x LP PCIe Gen3 x16 and x8 slots
- 1+1 1600W 80 PLUS Platinum redundant power supplies
* كل المعلومات المذكورة للاطلاع فقط. وتحتفظ جيجابايت بالحق في تعديلها أو مراجعتها في أي وقت دون اخطار مسبق.
* مستوى الأداء المعروض اعتماداً على أقصي القيم الافتراضية للواجهات والتي زودنا بها المصنعين المختلفين والذين وضعوا المعايير القياسية لهذه الواجهات. وقد يختلف مستوى الأداء الفعلي باختلاف مواصفات الحاسب.
* كل العلامات التجارية والشعارات هي ملك لحامليها.
* نظرأً لخصائص الحاسب القياسية، فإن قدراً من السعة الكلية للذاكرة يتم استخدامه من قبل الحاسب ولذلك تصبح سعة الذاكرة الحقيقية أقل من السعة المذكورة على وحدات الذاكرة.
* مستوى الأداء المعروض اعتماداً على أقصي القيم الافتراضية للواجهات والتي زودنا بها المصنعين المختلفين والذين وضعوا المعايير القياسية لهذه الواجهات. وقد يختلف مستوى الأداء الفعلي باختلاف مواصفات الحاسب.
* كل العلامات التجارية والشعارات هي ملك لحامليها.
* نظرأً لخصائص الحاسب القياسية، فإن قدراً من السعة الكلية للذاكرة يتم استخدامه من قبل الحاسب ولذلك تصبح سعة الذاكرة الحقيقية أقل من السعة المذكورة على وحدات الذاكرة.
SPECIFICATIONS
Dimensions (WxHxD, mm)
4U
482 x 175 x 696.6
482 x 175 x 696.6
Motherboard
MZ32-AR1
CPU
AMD EPYC™ 7003 Series Processors
AMD EPYC™ 7003 Series Processors with AMD 3D V-Cache™ Technology
AMD EPYC™ 7002 Series Processors
Single processor, 7nm technology
Up to 64 cores, 128 threads
cTDP up to 280W
AMD EPYC™ 7003 Series Processors with AMD 3D V-Cache™ Technology
AMD EPYC™ 7002 Series Processors
Single processor, 7nm technology
Up to 64 cores, 128 threads
cTDP up to 280W
Socket
1 x LGA 4094
Socket SP3
Socket SP3
Chipset
System on Chip
Memory
16 x DIMM slots
DDR4 memory supported only
8-Channel memory architecture
RDIMM up to 128GB supported
LRDIMM up to 128GB supported
3DS RDIMM/LRDIMM up to 256GB supported
Memory speed: Up to 3200*/2933 MT/s
*Follow BIOS setting and memory QVL if running 3200 MT/s with 2DPC.
DDR4 memory supported only
8-Channel memory architecture
RDIMM up to 128GB supported
LRDIMM up to 128GB supported
3DS RDIMM/LRDIMM up to 256GB supported
Memory speed: Up to 3200*/2933 MT/s
*Follow BIOS setting and memory QVL if running 3200 MT/s with 2DPC.
LAN
Rear side:
2 x 1Gb/s LAN ports (1 x Intel® I350-AM2)
Support NCSI function
1 x 10/100/1000 Mbps Management LAN
2 x 1Gb/s LAN ports (1 x Intel® I350-AM2)
Support NCSI function
1 x 10/100/1000 Mbps Management LAN
Video
Integrated in Aspeed® AST2500
2D Video Graphic Adapter with PCIe bus interface
1920x1200@60Hz 32bpp
2D Video Graphic Adapter with PCIe bus interface
1920x1200@60Hz 32bpp
Storage
Right & Left side:
24 x 3.5"/2.5" SATA/SAS hot-swappable bays
Front side:
4 x 2.5" Gen4 NVMe/SATA/SAS hot-swappable bays
8 x 2.5" Gen4 NVMe hot-swappable bays
12 x 2.5" SATA/SAS hot-swappable bays
Rear side:
2 x 2.5" SATA hot-swappable bays
1 x Broadcom SAS35x36R expander
Bandwidth: SATA 6Gb/s or SAS 12Gb/s per port
Default configuration supports:
12 x NVMe devices on the front side and 2 x SATA on the rear side
SAS card is required to enable the drive bays
Recommended SAS cards:
Broadcom 9500-16i Tri-Mode Storage Adapter
Broadcom 9560-8i Tri-Mode Storage Adapter
24 x 3.5"/2.5" SATA/SAS hot-swappable bays
Front side:
4 x 2.5" Gen4 NVMe/SATA/SAS hot-swappable bays
8 x 2.5" Gen4 NVMe hot-swappable bays
12 x 2.5" SATA/SAS hot-swappable bays
Rear side:
2 x 2.5" SATA hot-swappable bays
1 x Broadcom SAS35x36R expander
Bandwidth: SATA 6Gb/s or SAS 12Gb/s per port
Default configuration supports:
12 x NVMe devices on the front side and 2 x SATA on the rear side
SAS card is required to enable the drive bays
Recommended SAS cards:
Broadcom 9500-16i Tri-Mode Storage Adapter
Broadcom 9560-8i Tri-Mode Storage Adapter
SAS
Supported via SAS add-in cards
RAID
Depends on SAS add-in cards
Expansion Slots
Slot_6: PCIe x16 (Gen4 x16) low-profile slot, occupied by CNV3134 - 4 x Gen4 NVMe HBA
Slot_5: PCIe x16 (Gen4 x8) low-profile slot
Slot_4: PCIe x16 (Gen4 x16) low-profile slot, occupied by CNV3134 - 4 x Gen4 NVMe HBA
Slot_3: PCIe x16 (Gen4 x16) low-profile slot
Slot_2: PCIe x8 (Gen3 x0 or x8) low-profile slot
Slot_1: PCIe x16 (Gen3 x16 or x8) low-profile slot, shared with slot_2
1 x OCP 2.0 mezzanine slot with PCIe Gen3 x16 bandwidth (Type1, P1, P2, P3, P4)
Supports NCSI function
2 x M.2 slots:
- M-key
- PCIe Gen4 x4
- Supports 2242/2260/2280 cards
Slot_5: PCIe x16 (Gen4 x8) low-profile slot
Slot_4: PCIe x16 (Gen4 x16) low-profile slot, occupied by CNV3134 - 4 x Gen4 NVMe HBA
Slot_3: PCIe x16 (Gen4 x16) low-profile slot
Slot_2: PCIe x8 (Gen3 x0 or x8) low-profile slot
Slot_1: PCIe x16 (Gen3 x16 or x8) low-profile slot, shared with slot_2
1 x OCP 2.0 mezzanine slot with PCIe Gen3 x16 bandwidth (Type1, P1, P2, P3, P4)
Supports NCSI function
2 x M.2 slots:
- M-key
- PCIe Gen4 x4
- Supports 2242/2260/2280 cards
Internal I/O
1 x TPM header
Front I/O
2 x USB 3.0
1 x Power button with LED
1 x ID button with LED
1 x Reset button
2 x LAN activity LEDs
1 x Storage activity LED
1 x System status LED
1 x Power button with LED
1 x ID button with LED
1 x Reset button
2 x LAN activity LEDs
1 x Storage activity LED
1 x System status LED
Rear I/O
3 x USB 3.0
1 x VGA
1 x COM
2 x RJ45
1 x MLAN
1 x ID button with LED
1 x VGA
1 x COM
2 x RJ45
1 x MLAN
1 x ID button with LED
Backplane Board
Speed and bandwidth:
Front side - CBP20O7: PCIe Gen4 x4 or SATA 6Gb/s or SAS 12Gb/s
Rear side - CBPD020: SATA 6Gb/s
Right side - CBPD2C0: SATA 6Gb/s or SAS 12Gb/s
Left side - CBPD2C1: SATA 6Gb/s or SAS 12Gb/s
Front side - CBP20O7: PCIe Gen4 x4 or SATA 6Gb/s or SAS 12Gb/s
Rear side - CBPD020: SATA 6Gb/s
Right side - CBPD2C0: SATA 6Gb/s or SAS 12Gb/s
Left side - CBPD2C1: SATA 6Gb/s or SAS 12Gb/s
TPM
1 x TPM header with SPI interface
- Optional TPM2.0 kit: CTM010
- Optional TPM2.0 kit: CTM010
Power Supply
1+1 1600W 80 PLUS Platinum redundant power supplies
AC Input:
- 100-240V~/ 12-7A, 50-60Hz
- 200-240V~/ 9.5A, 50-60Hz
DC Input: (Only for China)
- 240Vdc/ 8A
DC Output:
- Max 1000W/ 100-240V~
+12V/ 80.5A
+12Vsb/ 3A
- Max 1600W/ 200-240V~ or 240Vdc Input
+12V/ 130.4A
+12Vsb/ 3A
AC Input:
- 100-240V~/ 12-7A, 50-60Hz
- 200-240V~/ 9.5A, 50-60Hz
DC Input: (Only for China)
- 240Vdc/ 8A
DC Output:
- Max 1000W/ 100-240V~
+12V/ 80.5A
+12Vsb/ 3A
- Max 1600W/ 200-240V~ or 240Vdc Input
+12V/ 130.4A
+12Vsb/ 3A
System Management
Aspeed® AST2500 management controller
GIGABYTE Management Console (AMI MegaRAC SP-X) web interface
GIGABYTE Management Console (AMI MegaRAC SP-X) web interface
- Dashboard
- HTML5 KVM
- Sensor Monitor (Voltage, RPM, Temperature, CPU Status …etc.)
- Sensor Reading History Data
- FRU Information
- SEL Log in Linear Storage/Circular Storage Policy
- Hardware Inventory
- Fan Profile
- System Firewall
- Power Consumption
- Power Control
- LDAP / AD / RADIUS Support
- Backup & Restore Configuration
- Remote BIOS/BMC/CPLD Update
- Event Log Filter
- User Management
- Media Redirection Settings
- PAM Order Settings
- SSL Settings
- SMTP Settings
OS Compatibility
Citrix Hypervisor 8.2.0 or later
Red Hat Enterprise Linux 8.3 (x64) or later
Red Hat Enterprise Linux 9.0 (x64) or later
SUSE Linux Enterprise Server 12 SP5 (x64) or later
SUSE Linux Enterprise Server 15 SP2 (x64) or later
Ubuntu 18.04.5 LTS (x64) or later
Ubuntu 20.04 LTS (x64) or later
Ubuntu 22.04 LTS (x64) or later
VMware ESXi 6.7 Update3 P03 or later
VMware ESXi 7.0 Update1 or later
VMware ESXi 8.0 or later
Windows Server 2016 (X2APIC/256T not supported)
Windows Server 2019
Windows Server 2022
Red Hat Enterprise Linux 8.3 (x64) or later
Red Hat Enterprise Linux 9.0 (x64) or later
SUSE Linux Enterprise Server 12 SP5 (x64) or later
SUSE Linux Enterprise Server 15 SP2 (x64) or later
Ubuntu 18.04.5 LTS (x64) or later
Ubuntu 20.04 LTS (x64) or later
Ubuntu 22.04 LTS (x64) or later
VMware ESXi 6.7 Update3 P03 or later
VMware ESXi 7.0 Update1 or later
VMware ESXi 8.0 or later
Windows Server 2016 (X2APIC/256T not supported)
Windows Server 2019
Windows Server 2022
System Fans
8 x 80x80x38mm (14,400rpm)
Operating Properties
Operating temperature: 10°C to 35°C
Operating humidity: 8-80% (non-condensing)
Non-operating temperature: -40°C to 60°C
Non-operating humidity: 20%-95% (non-condensing)
Operating humidity: 8-80% (non-condensing)
Non-operating temperature: -40°C to 60°C
Non-operating humidity: 20%-95% (non-condensing)
Packaging Dimensions
1100 x 700 x 483 mm
Packaging Content
1 x S472-Z30
1 x CPU heatsink
1 x 2-Section Rail kit
1 x CPU heatsink
1 x 2-Section Rail kit
Part Numbers
- Barebone package: 6NS472Z30MR-00-A*
- Motherboard: 9MZ32AR1NR-00
- 2-Section Rail kit (Supports CMA): 25HB2-A66123-C0R
- CPU heatsink: 25ST1-15320E-J1R
- Backplane board - CBP20O7: 9CBP20O7NR-00
- Backplane board - CBPD020: 9CBPD020NR-00
- Backplane board - CBPD2C0: 9CBPD2C0NR-00
- Backplane board - CBPD2C1: 9CBPD2C1NR-00
- Fan module: 25ST2-883829-D0R
- Power supply: 25EP0-21600B-F3S
Optional parts:
- Cable Management Arm: 25HBZ-R18100-K0R
- RMA packaging: 6NS472Z30SR-RMA-A100
- Motherboard: 9MZ32AR1NR-00
- 2-Section Rail kit (Supports CMA): 25HB2-A66123-C0R
- CPU heatsink: 25ST1-15320E-J1R
- Backplane board - CBP20O7: 9CBP20O7NR-00
- Backplane board - CBPD020: 9CBPD020NR-00
- Backplane board - CBPD2C0: 9CBPD2C0NR-00
- Backplane board - CBPD2C1: 9CBPD2C1NR-00
- Fan module: 25ST2-883829-D0R
- Power supply: 25EP0-21600B-F3S
Optional parts:
- Cable Management Arm: 25HBZ-R18100-K0R
- RMA packaging: 6NS472Z30SR-RMA-A100
* كل المعلومات المذكورة للاطلاع فقط. وتحتفظ جيجابايت بالحق في تعديلها أو مراجعتها في أي وقت دون اخطار مسبق.
* مستوى الأداء المعروض اعتماداً على أقصي القيم الافتراضية للواجهات والتي زودنا بها المصنعين المختلفين والذين وضعوا المعايير القياسية لهذه الواجهات. وقد يختلف مستوى الأداء الفعلي باختلاف مواصفات الحاسب.
* كل العلامات التجارية والشعارات هي ملك لحامليها.
* نظرأً لخصائص الحاسب القياسية، فإن قدراً من السعة الكلية للذاكرة يتم استخدامه من قبل الحاسب ولذلك تصبح سعة الذاكرة الحقيقية أقل من السعة المذكورة على وحدات الذاكرة.
* مستوى الأداء المعروض اعتماداً على أقصي القيم الافتراضية للواجهات والتي زودنا بها المصنعين المختلفين والذين وضعوا المعايير القياسية لهذه الواجهات. وقد يختلف مستوى الأداء الفعلي باختلاف مواصفات الحاسب.
* كل العلامات التجارية والشعارات هي ملك لحامليها.
* نظرأً لخصائص الحاسب القياسية، فإن قدراً من السعة الكلية للذاكرة يتم استخدامه من قبل الحاسب ولذلك تصبح سعة الذاكرة الحقيقية أقل من السعة المذكورة على وحدات الذاكرة.
SUPPORT
برامج تشغيل
BIOS
الأداة
Firmware
QVL
- All
- All
- Windows Server 2019
- Windows Server 2016 64bit
Chipset
Chipset
النسخة
الحجم
التاريخ
AMD Chipset Driver
For AMD EPYC 7002/ 7003
For AMD EPYC 7002/ 7003
Version : 2.10.09.156
17.22 MB
Mar 05, 2021
نظام التشغيل: Windows Server 2016 64bit,Windows Server 2019
LAN
LAN
النسخة
الحجم
التاريخ
Intel® LAN Driver and Utility
Version : 24.0
542.58 MB
Aug 06, 2019
نظام التشغيل: Windows Server 2016 64bit,Windows Server 2019
VGA
VGA
النسخة
الحجم
التاريخ
ASPEED Graphic Driver
Version : 1.06
1.78 MB
Aug 06, 2019
نظام التشغيل: Windows Server 2016 64bit,Windows Server 2019
BIOS
الوصف
النسخة
الحجم
التاريخ
1) Updated to AGESA RomePI 1.0.0.J.
2) Updated to AGESA MilanPI 1.0.0.D.
3) Included multiple security updates.
2) Updated to AGESA MilanPI 1.0.0.D.
3) Included multiple security updates.
Version : M23_R40
35.37 MB
Nov 04, 2024
1) Fixed PKfail Vulnerability.
2) Optimized BcpPro tool compatibility.
2) Optimized BcpPro tool compatibility.
Version : M22_R39
35.36 MB
Aug 26, 2024
Windows and UEFI mode flash BIOS SOP
Please download BIOS update tool from AMI Website
Please download BIOS update tool from AMI Website
-
0.31 MB
Jan 29, 2021
Warning:
نظرأ لأ عملية تحديث وحدة التشغيل الرئيسية بها قدر من المخاطرة، نوصي بألا تحاول تحديثها إذا لم تقابلك مشاكل تستدعي ذلك. عند تحديث وحدة التشغيل الرئيسية، تعامل بحرص. التحديث الخاطىء قد ينتج عنه مشاكل في الحاسب
What is a BETA?
النسخة BETA تصف نسخة حديثة وجاهزة للاستخدام إلا أنها قد لا تحتوي على كل الخصائص المتضمنة في النسخة النهائية وتستهدف جمع المعلومات من المستخدمين بما يسهم في الحصول على أفضل تجربة ممكنة
نظرأ لأ عملية تحديث وحدة التشغيل الرئيسية بها قدر من المخاطرة، نوصي بألا تحاول تحديثها إذا لم تقابلك مشاكل تستدعي ذلك. عند تحديث وحدة التشغيل الرئيسية، تعامل بحرص. التحديث الخاطىء قد ينتج عنه مشاكل في الحاسب
What is a BETA?
النسخة BETA تصف نسخة حديثة وجاهزة للاستخدام إلا أنها قد لا تحتوي على كل الخصائص المتضمنة في النسخة النهائية وتستهدف جمع المعلومات من المستخدمين بما يسهم في الحصول على أفضل تجربة ممكنة
- All
- All
- Windows Server 2022
- Windows Server 2019
- Windows Server 2016 R2 64bit
- Windows Server 2016 64bit
- Windows Server 2012 R2 64bit
- Windows Server 2012 64bit
- Windows 10 64bit
- VMware
- Ubuntu
- Linux CentOS
- Linux
الأداة
الوصف
النسخة
الحجم
التاريخ
GSM CLI
Version : 2.1.77
147.89 MB
Sep 27, 2024
نظام التشغيل: Windows Server 2012 64bit,Windows Server 2012 R2 64bit,Linux CentOS,Windows 10 64bit,Ubuntu,Windows Server 2016 R2 64bit,Windows Server 2019,Windows Server 2022
GSM Server
Version : 2.12
926.33 MB
Jan 18, 2023
نظام التشغيل: Linux,Windows Server 2016 64bit,Windows Server 2019
GSM Agent
Version : 2.5
720.29 MB
Dec 27, 2021
نظام التشغيل: Linux,Windows Server 2016 64bit,Windows Server 2019
BMC Restore Default Setting utility
Version : 1.0
0.15 MB
Mar 17, 2020
نظام التشغيل: Ubuntu
Firmware
الوصف
النسخة
الحجم
التاريخ
BMC Firmware with embedded GIGABYTE Management Console
(AST2500 AMI)
(AST2500 AMI)
Version : 12.61.21
105.38 MB
Apr 11, 2024
الانجليزية
دليل المستخدم
الوصف
النسخة
الحجم
التاريخ
User Guide - GIGABYTE Management Console (AMI)
Version : 1.0
14.16 MB
Jun 10, 2020
الانجليزية
الوصف
النسخة
الحجم
التاريخ
RESOURCES
Articles
Tech Guide | May 31, 2022
What is Private Cloud, and is it Right for You?
In the era of cloud computing, just about everyone has heard of the terms “private cloud” and “public cloud”. Chances are, you are using one or both of them in your everyday life—but how much do you really know about them? If you had the chance, could you build a private cloud for yourself or your organization? GIGABYTE Technology, an industry leader in server solutions used by global cloud service providers, is pleased to present our latest Tech Guide. We will examine the difference between private and public clouds, introduce the private cloud’s advantages and limitations, and then introduce GIGABYTE products that may help you build and operate a private cloud of your own.
News
News | May 30, 2022
GIGABYTE Joins ISC High Performance 2022 to Promote Emerging Enterprise Technologies, Including Accelerated Computing
Others
Back to S472-Z30